The Rapid RH™ is intended for interior use only. It is imperative that the interior
application area be protected from weather elements such as rain and snow to
prevent water intrusion. The Rapid RH™ is not to be used in concrete less than
28 days old. Follow
ASTM F2170-02, Standard Test Method for Determining
Relative Humidity in Concrete Floor Slabs using in situ Probes
1
.
NIST
2
traceable accuracy:
Readings at +/- 2% from 50% to 90% (at service conditions
1
)
Readings at +/- 3% up to 97% (at service conditions
1
)
Avoid severe cold or hot storage environments (i.e. vehicles)
1Available from ASTM International, P.O. Box C700, West Conshohocken, PA 19428-2959, http://www.astm.org
2National Institute of Standards and Technology
It is important to avoid condensation on the Rapid RH™ Smart Sensor. If the
sensor is colder than the dew point temperature of the environment being tested,
condensation can occur causing inaccurate readings and potentially damaging
the sensor. To avoid condensation on the sensor allow the probes to stabilize at
room temperature before removing from the package. This action is especially
important if you bring the Rapid RH™ Smart Sensor from a cold environment
(such as an unheated area of a vehicle) into a building.
Avoiding Condensation
Use Conditions
Wagner Electronic Products, Inc. warrants the Rapid RH™ Smart Sensor and Rapid RH™ Reader product against defects in material and workmanship for one (1) year from
the date of purchase, subject to the following terms and conditions:
Wagner’s liability under this warranty shall be limited, at Wagner’s option, to the repair or replacement of this product or any part thereof, which is demonstrated to be
defective. To exercise this warranty, customer must telephone, fax or e-mail Wagner’s Customer Service Department for a RMA (Return Materials Authorization) number and
factory instructions for shipment. This limited warranty does not apply if the product has been damaged by accident, negligent handling, misuse, alteration, damage during
shipment, or improper service. Wagner Electronic Products, Inc. shall in no event be liable for any breach of warranty or defect in this product, which exceeds the amount of
purchase price of the product.
With proper care and handling, the product should stay in calibration; however, because Wagner Electronic Products, Inc. has no control over the manner in which the unit
will be used, it makes no warranty that the Smart Sensors will stay in calibration for any specific period of time.
This warranty is in lieu of all other warranties, whether oral or written, express or implied. Any implied warranties, including implied warranties of merchantability
and fitness for a particular purpose, are excluded.
If this product is not in good working order as warranted above, the customer’s sole remedy shall be repair or
replacement as provided above.
This warranty is personal to the customer purchasing the product from Wagner Electronic Products, Inc. or from its authorized distributors and is not transferable.
The agents and employees of Wagner Electronic Products, Inc. are not authorized to make modifications of this warranty or additional warranties binding on
Wagner Electronic Products, Inc. Accordingly, additional statements, whether oral or written, except written statements from an officer of Wagner Electronic Products, Inc. do
not constitute warranties and should not be relied upon by the customer.
Wagner Electronic Products, Inc.
LIMITED WARRANTY
For more information on Relative Humidity Testing
and to order online go to
www.rapidrh.com
500-RRP01-002
326 Pine Grove Road
Rogue River, OR 97537
(800) 207-2164
The RAPID RH™ is registered under U.S. Patent 7,231,815
Patents Pending
Wagner Electronics
®
©Wagner Electronic Products, Inc. 2005
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the publisher.