SET-UP FOR TESTING
Installation of the Sensor Head
No matter what style of exhaust system your vehicle has, the Full Flow style attaches the same
way. Engage the magnetic hook over the lip of the pipe and fasten the band clamp using the
latch and hair pin. Once the magnetic bland clamp it fastened, loosen the nut and bolt and
rotate the yoke into position so that the beam is centered over the opening of the exhaust and
is about 1-2 inches from the end of the pipe. The full flow head never touches the flow of
exhaust and is best for long duration testing, including tests that are performed using a
Dynamometer. Ensure the beam of light is parallel to the ground.
Caution:
Ensure the sensor head has been powered on and self-calibrated before affixing the sensor
head to the exhaust. If you self-calibrate the unit while the sensor head is in the flow of exhaust, the
equipment will see the exhaust, think the exhaust is the normal dust in the air, and call it zero.