background image

W A G E N E R

Fairburn

Installation, Operation & Maintenance

INSTRUCTIONS

Designed & Handcrafted in New Zealand

Designed & Handcrafted in New Zealand

Summary of Contents for Fairburn

Page 1: ...W A G E N E R Fairburn Installation Operation Maintenance INSTRUCTIONS Designed Handcrafted in New Zealand Designed Handcrafted in New Zealand ...

Page 2: ...ualise for 15 20 minutes Now your oven is ready for use Place your food in the oven close the oven door and your oven should maintain its temperature If additional wood is required first open the flue control to spill fire gases directly up the flue Using the tool provided lift the hot plate situated directly above the fire box up 5mm for 1 2 seconds then remove to add the required wood and then r...

Page 3: ...solid fuel heating appliances are installed Permits will not be signed off if alarms are not fitted Important Message to the Installer These installation instructions are the results of performance tests on the Wagener Free Standing Multi Fuel Cooking Range Fairburn Radiant in accordance with AS NZ 2918 2001 Domestic Solid Fuel burning appliances Installation Clearance tests were carried out by an...

Page 4: ...ector shall have an upper surface including grouting if required of a durable non combustible material eg Tiles slate treadle plate etc All joints in the surface must be sealed to protect and prevent ash or spilled embers reaching the floor Floor protection shall extend under the cooker and not less than the width of the cooker and shall extend forward 300mm and be 200mm from the side of the fireb...

Page 5: ...nd odour for rt period This is a temporary condition Open doors and windows to give adequate ventilation please dditional sheet on paint supplied with these instructions To condition the firebricks your first 2 3 fires be small rt Up Rotate the air control black round plate beneath the firebox door glass to the open position so that the widest air opening is obtained Caution refer Over firing sect...

Page 6: ...OOD FIRE AND FLUE CLEARANCES FROM COMBUSTIBLEWALLS MUST BE IN ACCORDANCEWITHWOOD FIRE MANUFACTURER S SPECIFICATIONS AND AS NZS 2918 2001 TheWagener Fairburn uses a 150mm diameter flue It is imperative that the connection between the flue and the flue flange is sealed using a suitable flue sealant fire cement If an offset bend is required it should be as steep as possible to enable ease of cleaning...

Page 7: ...ximately 25mm x 25mm can be fitted under the flashing to securely fix the roof to the OUTER CASING 6 Drill holes in CEILING PLATE for the fixing screws Place CEILING PLATE over Wood Fire FLUE FLANGE ensuring the folded edges are facing the ceiling 7 Position bottom length of FLUE PIPE crimped end downwards into the FLUE FLANGE 8 Use fire cement to seal the joint where the bottom section of FLUE PI...

Page 8: ...PENING FIRE BOX DOOR 7 CAUTION THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED GLASS 8 CAUTION THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS 9 CAUTION THE USE OF TREATED WOOD AS A FUEL CAN BE HAZARDOUS TO THE ENVIRONMENT AND DETRIMENTAL TO YOUR APPLIANCE Further Cautions Over Firing DO NOT run the Fairburn with the door ajar or open This w...

Page 9: ...ooking surface and located below and forward of the flue flange collar This control is open in the east west position and allows the flue gases to travel directly up the flue and closed in the north south position diverting gases and heat down the firebox side of the oven across under the base of the oven up the other side across the top of the oven and then up the flue And two tools 1 The Poker S...

Page 10: ...o heat up Never cook food directly on top of the top plates Always use pots pans and appropriate cooking implements When bringing pots to the boil or requiring high heat use top plates directly over the firebox Move cooking vessels further towards the oven side for slower cooking and lower heat A suitable raised trivet on the top can provide even slower cooking options Avoid spills which can be de...

Page 11: ...st be replaced with a 5mm robax ceramic glass This should be purchased through your Wagener Stoves Dealer as the glass tape fitting is critical NOTE Do not operate your Fairburn with broken door glass and under no circumstance should a non ceramic type glass be used as it may explode due to the intense heat inside the fire box Door Seals Flue Flange and Secondary Air Tube The firebox door seal sho...

Page 12: ...ves Lion Ltd reserves the right to change specifications or design of its products without prior notice WAGENER STOVES LION LTD 5 Allen Bell Drive KAITAIA NZ Phone Fax 09 408 2469 www wagenerstoves co nz 2017 2021 ...

Reviews: