background image

 

 

 

 

                                                                

Part 1: INSTALLATION INSTRUCTIONS     

            FOR THE BUTLER MULTI 

(Please keep these Instructions for future Reference)       

 

Important Message to the Owner 

 

Please read fully the Operation & Maintenance Instructions with your Butler Multi 

BEFORE lighting

 your 

first fire. Your insurance company may require notification of the installation. Please check. 

When a Wet Back is fitted it must be connected to the water supply or damage will result

.  

Such damage is not covered by Warranty. Tempering Valves should be installed to the system for safety. 

Tempering Valves may be a Permit Requirement. Check with your Building Inspector or Local Council.  

BIA: As from 22 April 2003 Automatic Smoke Detectors/Alarms will be mandatory in all new homes and 

when solid fuel heating appliances are installed. Permits will not be signed off if alarms are not fitted. 

 

Important Message to the Installer  

The Butler Multi has been tested to and complies with AS/NZS 2918:2001- Domestic Solid Fuel 

Burning Appliances 

The Butler Multi must be installed in accordance with these installation instructions to comply with AS/NZ 

2918-2001-Domestic Solid Fuel burning appliances. 

 

Installer’s Responsibilities 

 

Installation of the Butler Multi must be in accordance with these instructions. 

Any variation from these installation instructions or any doubts about them must be checked against 

requirements of the AS/NZS 2918-2001.The installation must be carried out by a suitably qualified installer. 

We recommend using an NZHHA Accredited Technician. 

 

WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN 

ACCORDANCE WITH AS/NZS 2918: 2001 AND THE APPROPRIATE REQUIREMENTS OF 

THE RELEVENT BUILDING CODE OR CODES. 

 

THE APPLIANCE AND FLUE SYSTEM SHOULD NOT BE MODIFIED IN ANY WAY 

WITHOUT THE WRITTEN APPROVAL OF THE MANUFACTURER. 

 

WARNING: DO NOT CONNECT WET BACKS TO AN UNVENTED HOT WATER SYSTEM 

 

INSTALL IN ACCORDANCE WITH AS 3500.4.1 OR NZS 4603 AND THE APPROPRIATE 

REQUIREMENTS OF THE RELEVENT BUILDING CODE OR CODES 

 

CAUTION: MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR 

MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS 

CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE 

CONSULTED IN THE FIRST INSTANCE. 

 

CAUTION: CRACKED AND BROKEN COMPONENTS, e.g. GLASS PANELS OR FIRE BRICKS MAY 

RENDER THE INSTALLATION UNSAFE. 

 

Flue System  

 

Must be manufactured in accordance with AS/NZ 2918-2001 and tested to Appendix F. See installation 

instruction section on page 5. 

 

PLEASE LEAVE THESE INSTRUCTIONS WITH THE OWNER WHEN THE INSTALLATION IS COMPLETED 

Summary of Contents for BUTLER MULTI

Page 1: ...Butler Multi must be in accordance with these instructions Any variation from these installation instructions or any doubts about them must be checked against requirements of the AS NZS 2918 2001 The...

Page 2: ...NOTE THE BUTLER MULTI MUST BE AFFIXED TO THE HEARTH AND FLOOR FOR SEISMIC RESTRAINT For Seismic Restraint use two holes in the base at the rear and screw through the hearth and into the floor NOTE FO...

Page 3: ...wall 25mm 25mm Ash Hearth Floor Protection must extend under the stove and forward 300mm extending 200mm either side of the door opening Other screening materials are available and clearance factors...

Page 4: ...top of the flue system should be at least 1000mm above the roof or at least 600mm higher than any obstacle or ridge within 3 metres of the flue A total minimum vertical flue height ABOVE the Butler Mu...

Page 5: ...have to be added to ensure the correct roof penetration heights are obtained 5 Fix an appropriate flashing around the OUTER HEAT SHIELD to seal onto the roofing material 6 From the roof slide the INNE...

Page 6: ...CONTROLTO FULL AIR SUPPLY BEFORE OPENING FIRE DOOR 7 CAUTION THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED GLASS 8 CAUTION THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCO...

Page 7: ...gh temperature paint used on the Butler Multi will give off smoke and odour for a short period This is a temporary condition Open doors and windows to give adequate ventilation To condition the firebr...

Page 8: ...ing seasoned fuel the glass in your Butler Multi should remain relatively clear If the glass becomes dirty it can be cleaned by dipping a damp paper towel into the dry cold ashes and rubbing gently on...