WAGAN Corp. Limited Warranty

The WAGAN Corporation warranty is limited to products sold only in 

the United States. 

Warranty Duration: 

Product is warranted to the original purchaser for a period of from the original 

purchase date, to be free of defects in material and workmanship. WAGAN 

Corporation disclaims any liability for consequential damages. In no event will 

WAGAN Corporation be responsible for  any amount of damages beyond the amount 

paid for the product at retail. 

Warranty Performance: 

During the warranty period, a product with a defect will be replaced with a 

comparable model when the product is returned to WAGAN Corporation with an 

original store receipt. WAGAN Corporation will, at its discretion, replace or repair 

the defective part. The replacement product will be warranted for the balance of the 

original warranty period.  This warranty does not extend to any units which have been 

used in violation of written instructions furnished. 

Warranty Disclaimers: 

This warranty is in lieu of all warranties expressed or implied and no representative 

or person is authorized to assume any other liability in connection with the sale of our 

products. There shall be no claims for defects or failure of performance or product 

failure under any theory of tort, contract or commercial law including,but not limited 

to negligence, gross negligence, strict liability, breach of warranty, and breach of 

contract. 

Returns: 

WAGAN Corporation is not responsible for any item(s) returned without an official 

Return Authorization number (RA#). Please contact our customer service team by 

phone or email to obtain an RA#. You can also visit our website and chat with our team 

during our normal business hours. For more details and instructions on how to process 

a warranty claim, please read the “Returns” section under the “Contact” page on our 

website. WAGAN Corporation is not responsible for any shipping charges incurred in 

returning the item(s) back to the company for repair or replacement.
Register your product online at http://tinyurl.com/wagan-registration to be added to 

our email list. You will receive previews on our upcoming products, promotions, and 

events.
 

©2015

Summary of Contents for Proline-5000 3744

Page 1: ...Item No 3744 12V DC Input 3744 4 24V DC Input 3744 8 48V DC Input Proline 5000 AC to DC Inverter User s Manual Please visit our website for the latest information on this product RoHS compliant...

Page 2: ...Output AC Terminals 6 Remote ON OFF Switch Connection 6 Power Inverter Output Waveform 6 Inverter Output Characteristics 7 Rear Panel 7 High Speed Cooling Fan 7 Negative DC Input and Positive DC Input...

Page 3: ...onnecting an Inverter 12 General information 12 Ground Terminal Wire Requirements 12 Cable Preparation 12 Inverter to Battery Connection Procedure 13 Charging the Battery Bank 14 Regular Loss of Comme...

Page 4: ...ing fumes from flooded lead acid batteries Keep well ventilated this device generates heat Do not continuously operate your inverter at more than its rated output wattage Incorrect battery polarity wi...

Page 5: ...e equipment All Modified Sine Wave MSW inverters may not properly operate some appliances with either speed control features or dimmer controls Some appliance GFCI power cords will not operate properl...

Page 6: ...verter These are used to help diagnose problems if they occur Volts Display The volts display is the measurement of the voltage at the DC terminals of the inverter not actual battery voltage During hi...

Page 7: ...nnection to distributed wiring that has multiple AC outlets Any wiring that is directly connected must be 10 gauge or larger Facing the front panel the terminals are Top Middle Bottom Live Black Neutr...

Page 8: ...gh Speed Cooling Fan Positive DC Input Terminal High Speed Cooling Fan Fans operate automatically when the internal temperature of the inverter requires cooling Always allow free air flow Do not block...

Page 9: ...otorized appliances will cause Do not exceed the surge rating of this inverter 5 000 watts this can cause immediate overload shut down At 5 000 watts continuous output this inverter requires a DC powe...

Page 10: ...ged at a 1 amp rate is will take 20 hours to discharge that battery The terms charged and discharged relate to actual battery voltage This means that the output voltage of a nominal 12 volt battery st...

Page 11: ...ries are flooded type they freely vent hydrogen and oxygen while under charging and heavy discharge They must be vented to outside air to prevent accumulation of explosive gases If the batteries are t...

Page 12: ...protection Safety Ground 12V 220Ah 12V 220Ah 12V 220Ah INVERTER 12V DC Input Safety Ground 12V 220Ah 12V 220Ah 12V 220Ah 12V 220Ah 12V 220Ah 12V 220Ah INVERTER 24V DC Input Safety Ground 48V DC Input...

Page 13: ...to the positive terminal of the battery bank Use a length of string and follow the route the cables will follow Measure the length of string and then determine the correct gauge cable required for the...

Page 14: ...erminals on the rear of the inverter 4 Tighten the retaining nuts 5 Connect all fuses end positive cable ring terminals to the positive battery bank terminal 6 Carefully tighten the retaining nuts DO...

Page 15: ...charger manual s s WARNING THERE IS DANGER OF EXPLOSION DO NOT CONNECT OR DISCONNECT CHARGER CABLES DIRECTLY AFTER BATTERY DISCHARGE OR RECHARGE MAKE SURE THAT THE BATTERY BANK AREA IS WELL VENTED BE...

Page 16: ...ed value Recharge or replace battery Equipment being operated draws too much power Cable gauge may be inadequate use heavier cables Inverter is too hot thermal shut down mode Allow inverter to cool Ch...

Page 17: ...DC 0 2A DC Battery low alarm 3744 10 5V 0 5V DC 3744 4 21 0V 1 0V DC 3744 8 42 0V 2 0V DC Battery low shutdown 3744 9 5V 0 5V DC 3744 4 20 0V 1 0V DC 3744 8 40 0V 2 0V DC AC output sockets 3 US standa...

Page 18: ...battery negative to inverter negative Use this Total Cable Length to determine the correct cable gauge in table in Appendix A Fuse Battery Bank INVERTER Positive Cable Positive Cable Negative Cable To...

Page 19: ...warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume any other liability in connection with the sale of our products There shall be no cl...

Page 20: ...CA 94544 U S A Tel 1 510 471 9221 U S Canada Toll Free 1 800 231 5806 customerservice wagan com www wagan com 2016 Wagan Corporation All Rights Reserved Wagan Tech and wagan com are trademarks used b...