background image

Slim Line 1750 Watt Power Inverter by Wagan Tech 

USER’S MANUAL — Please read before using this equipment. 

_______________________________________________________________________________________________________________________

HEAT DISPERSAL

The inverter generates heat while it is working. This is 
not a malfunction. However, if the inverter gets too hot
while working, it will turn off by itself. 
Position the inverter where air flows freely around it to 
allow the heat to disperse.
The inverter’s thermal protection prevents it from 
operating when its temperature exceeds 130 ± 10 

q

F / 55 

± 5 

q

C.

SPECIFICATION

Name

Description

Input

12V (10-15V) DC 

Output

1750V AC

Output frequency

60 Hz 

Output waveform

Modified sinewave,phase corrected

Continuous power

1750 Watt 

Surge power

3500 Watt 

Efficiency

Approx. 85-90 % 

No load current

< 0.3 A 

Battery low alarm

10.5 ± 0.5 V DC 

Battery low shutdown

10 ± 0.5 V DC 

Alarm and thermal
shutdown

130 ± 10 

q

F / 55 ± 5 

q

C

Internal DC fuse

30 A 

External DC fuse

None

AC output socket

2 outlets of 3-prong

Power switch

DC input ON/OFF control

Dimensions (LxWxH) 

15x8x3.3 in³

Net Weight

10 lb 

NOTE

All specifications are typical at nominal line, half load,
and 77 

q

F / 25 

q

C unless otherwise noted.

Specifications are subject to change without notice. 

www.wagan.com

All Rights Reserved. 

Wagan and Wagan.com are trademarks used by Wagan Corporation.

Printed in China

© 2003 Wagan Corporation.

5

Summary of Contents for Inverter

Page 1: ...User s Manual Item no 2006 R TM 1750 1750 1750 ...

Page 2: ...rom inverter to Ջ of battery terminal x Turn ON the power switch that is located at the front of the inverter and the green LED light will light as indicator that the unit at work x Insert the plug of your appliances into AC socket at the front of the inverter CAUTION x DO NOT USE THE INVERTER IN A POSITIVELY GROUNDED VEHICLE RECOMMENDATION x If the power inverter makes a beeping sound turn OFF th...

Page 3: ...rm of the AC inverter is a MODIFIED SINEWAVE To measure the AC output voltage you must use a TRUE RMS VOLTMETER SAFETY PRECAUTION Do not open the case of the inverter The high voltage inside the unit is the same type of power as your electrical outlets at home Do not let the cord of the inverter or any appliance s cord get wet Do not operate the inverter in or around water The voltage of the unit ...

Page 4: ...ng Television interference Operating of the power inverter can interfere with television reception on some channels If this situation occurs the following steps may help to alleviate the problem 1 Make sure that the chassis ground lug on the back of the power inverter is solidly connected to the ground system of your vehicles 2 Do not operate high power loads with the power inverter while watching...

Page 5: ...CATION Name Description Input 12V 10 15V DC Output 1750V AC Output frequency 60 Hz Output waveform Modified sinewave phase corrected Continuous power 1750 Watt Surge power 3500 Watt Efficiency Approx 85 90 No load current 0 3 A Battery low alarm 10 5 0 5 V DC Battery low shutdown 10 0 5 V DC Alarm and thermal shutdown 130 10 qF 55 5 qC Internal DC fuse 30 A External DC fuse None AC output socket 2...

Page 6: ... of written instructions furnished Warranty Disclaimers This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume any other liability in connection with the sale of our products There shall be no claims for defects or failure of performance or product failure under any theory of tort contract or commercial law including but not limited ...