Elite 1500W—Pure Sine Inverter 

by Wagan Tech

©2010 Wagan Corporation

All Rights Reserved

Wagan and wagan.com are trademarks used by Wagan Corporation

14

User’s Manual—Read before using this equipment

11.  Turn OFF (0) the inverter. The Fault LED may briefly “flash”. This is 

normal. The audible alarm may also sound a short “chirp”. This is  
also normal. 

12.  When you have confirmed that the appliance to be operated is turned 

off, plug the appliance into one of the two AC outlets on the front panel 
of the inverter. 

13.  Turn the inverter on. 
14. Check operation of the Remote Switch – Press “Lock” to turn Off   

the inverter. 

15.  Press the Unlock button to turn On the inverter.
16. Turn the appliance on. The appliance should begin working. 
17.  Observe the LED indicators and the Digital Display for Normal 

operation.

Note: If an extension cord is used from the inverter to the appliance, limit the 
extension cord length to 100 feet or less. Make sure that the cord is safety 
approved and AWG 14 or greater to carry the appliance load. Remember 
that extension cords are for temporary use.

Charging the Battery Bank 

It is not the purpose of this inverter user’s guide to provide detailed information 
regarding battery charging systems. However, the user should try to augment 
any stationary inverter charging system with either wind power or solar 
power. These can continue to operate during power outages and they also 
reduce recharge time. For mobile or marine charging systems, a higher rated 
alternator may be necessary to charge a battery bank.

Regular Loss of Commercial Power 

If the inverter system is used during commercial power outages that occur 
daily, configure the charger system to replace energy during the time that 
commercial power is available. 

Replacement of battery energy always requires more than was taken from 
the battery (typically 30 percent more). Follow battery manufacturer’s 
recommendations for maximum charging current.

Warning: 

T

here

 

is

 

danger

 

of

 

explosion

. do noT 

connecT

 

or

 

disconnecT

 

charger

 

cables

 

direcTly

 

afTer

 

baTTery

 

discharge

 

or

 

recharge

make

 

sure

 

ThaT

 

The

 

baTTery

 

bank

 

area

 

is

 

Well

 

venTed

 

before

 

aTTaching

 

or

 

removing

 

cables

If the flooded lead acid batteries are used, be sure that periodic checks of 
battery electrolyte levels are accomplished. Follow battery manufacturer’s 
instructions in keeping the electrolytes at the proper level. Be sure to use pure 
distilled water when replacing evaporated electrolyte liquid. 

Operating Issues 

(Television and Audio Equipment Suggestions.)

Although all inverters are shielded and filtered to minimize signal interference, 
some interference with your television picture may be unavoidable, especially 
with weak signals. However, here are some suggestions that may improve 
reception. 

•  Make sure that the television antenna produces a clear signal under 

normal operating conditions (i.e. at home plugged into a standard 
110/120V AC wall outlet). Also ensure that the antenna cable is properly 
shielded and of good quality. 

•  Sometimes vehicle alternators produce some electrical noise. There are 

filters available to mount on the alternator to reduce noise.

•  Change the positions of the inverter, antenna cables and television  

power cord. 

•  Isolate the television, its power cord and antenna cables from the 12 

volt power source by running an extension cord from the inverter to the 
television set. 

Summary of Contents for Elite 1500W

Page 1: ...item 2204 User s Manual SHEMO080100244TXC ...

Page 2: ...ng this inverter Keep this manual for future use About This Inverter This power inverter converts 12 volts direct current 12V DC to 120 volts alternating household current 120V AC It easily powers TV VCR combinations small microwave ovens and refrigerators It also operates at high efficiency up to 90 that results in long running time and extended battery life compared to other inverters with this ...

Page 3: ...ssive load for the cables can cause a low voltage reading and inverter shutdown Low battery is also indicated when the Audible Alarm sounds An alternative display shows the Percent of Load that the inverter can handle If the inverter has excessive load OVL will be displayed USB Power Port This USB Power Port provides 5 Volts DC to charge cell phones personal media players and a host of USB powered...

Page 4: ...turn the inverter Off momentarily press Lock If the wireless remote fails to control operation of the inverter you may be out of range for the radio signal move closer to the inverter If the Remote Switch has a depleted battery open the unit by unscrewing the three small screws on the back side of the remote control and replace the 12 volt model 23A alkaline battery with a new one Rear Panel Posit...

Page 5: ... total watt hours of energy needed This is done by multiplying average power consumption in watts by hours of run time For example 500 watts for 10 hours 5000 watt hours To get an estimate of the maximum current in amps that a battery bank must be capable of delivering to the inverter divide the load watts by ten For example a 500 watt appliance load Load Considerations When an appliance with a mo...

Page 6: ...tage This means that the output voltage of a nominal 12 volt battery starts at 13 4 volts fully charged then drops to 10 5 volts discharged If the load on the battery causes the battery to discharge faster than the 20 hour rate the capacity AH of the battery is measurably reduced derated In heavy battery discharge applications double the estimated Amp Hour rating and configure batteries to support...

Page 7: ... to the chassis of your vehicle or to the grounding system in your boat In a city the ground wire can connect to a metal cold water pipe that goes underground In remote locations the ground wire can be connected to an earth ground This can be an attachment to a foot long copper clad metal rod driven into the ground In the unlikely event of a short circuit operating the inverter without proper grou...

Page 8: ... the inverter system is used during commercial power outages that occur daily configure the charger system to replace energy during the time that commercial power is available Replacement of battery energy always requires more than was taken from the battery typically 30 percent more Follow battery manufacturer s recommendations for maximum charging current WARNING There is danger of explosion DO ...

Page 9: ...ous power output Unit may be defective See warranty and call customer service PROBLEM Inverter Shut Down Fault LED Lit OVL Display Reason Solution Equipment being operated draws too much power Use a higher capacity inverter or do not use this equipment PROBLEM Continuous Buzzing Sound Display Shows Low Voltage Reason Solution Input voltage below 10 5 Volts Keep input voltage above 10 5 Volts Poor ...

Page 10: ...rsonnel or other causes not arising out of defects in materials or workmanship This warranty is effective only if the product is purchased and operated in the USA and does not extend to any units which have been used in violation of written instructions furnished Warranty Disclaimers This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to as...