12V Battery Bank

www.wagan.com

9

Elite 1500W—Pure Sine Inverter 

by Wagan Tech

©2010 Wagan Corporation

All Rights Reserved

Wagan and wagan.com are trademarks used by Wagan Corporation

10

User’s Manual—Read before using this equipment

will need 50 amps at 12 volts DC. Using the 500 watts (or 50 amps) for 10 
hours example as above, then 50 amps is needed for 10 hours. This provides 
us with the basic amp-hours (AH) of battery that is required. Ten hours at 50 
amps equals 500 amp-hours (AH). There are additional factors that determine 
actual run time. These include: 

•  AC appliance load and time in use (basic AH). 
•  Cable gauge and length (cable losses). 
•  Charge level of the batteries (between use, chargers have to be able  

to fully charge the batteries). 

•  Temperature of the batteries (colder batteries provide fewer amps). 
•  Age and condition of the batteries (older batteries lose AH capacity). 
•  Compliance with turning off unnecessary AC loads. 
•  Use of DC appliances and compliance with turning off unnecessary  

DC loads. 

Derating the Battery Bank 

Most lead-acid batteries have a rating expressed in amp-hours (AH). The most 
common rating of AH is “at the 20 hour rate”. 

NOTE: Despite several internet explanations, there is no relationship between 
cold cranking amps (CCA) and ampere-hours (AH). 

For example, if a 20 AH battery is discharged at a 1 amp rate, is will take 20 
hours to discharge that battery. The terms “charged” and “discharged” relate 
to actual battery voltage. This means that the output voltage of a nominal 
12 volt battery starts at 13.4 volts (fully charged) then drops to 10.5 volts 
(discharged). If the load on the battery causes the battery to discharge faster 
than the 20 hour rate, the capacity (AH) of the battery is measurably reduced 
(derated). In heavy battery discharge applications, double the estimated Amp 
Hour rating and configure batteries to support this capacity. If the batteries are 
frequently charged by an alternator, the Amp Hour rating of the battery may 
be reduced. 

Configuring the battery bank 

Batteries that are used indoors or inside a vehicle or vessel, should be deep-
cycle, sealed lead acid batteries. 

NOTE: It is important that for any inverter installation to battery protection 
fuses. Battery fuses are added to the positive (+) battery cable as close as 
possible to the battery bank’s positive terminal. The fuse amperage rating 
must be sized to allow simultaneous operation of all the AC appliances 
to be powered, plus 20 percent safety factor. Fuses are very important to 
protect equipment, batteries and personnel. The fuses protect against battery 
explosion if the cables that connect to the inverter accidentally short. 

Battery Bank Diagram 

The diagram below shows inverter connections to a battery bank with 
recommended fuse protection. 

 Fuse

WARNING—Exploding Batteries!!

e

xploding

 

baTTeries

 

can

 

spray

 

molTen

 

lead

hoT

 

sulfuric

 

acid

and

 

oTher

 

meTal

 

and

 

plasTic

 

fragmenTs

. b

aTTeries

 

ThaT

 

are

 

charging

 

or

 

under

 

high

 

discharge

 

raTes

 

produce

 

explosive

 

hydrogen

 

gas

 

inTo

 

The

 

surrounding

 

area

. b

e

 

safe

fuse

 

The

 

baTTery

 

bank

 

and

 

make

 

sure

 

The

 

baTTeries

 

are

 

properly

 

venTilaTed

Summary of Contents for Elite 1500W

Page 1: ...item 2204 User s Manual SHEMO080100244TXC ...

Page 2: ...ng this inverter Keep this manual for future use About This Inverter This power inverter converts 12 volts direct current 12V DC to 120 volts alternating household current 120V AC It easily powers TV VCR combinations small microwave ovens and refrigerators It also operates at high efficiency up to 90 that results in long running time and extended battery life compared to other inverters with this ...

Page 3: ...ssive load for the cables can cause a low voltage reading and inverter shutdown Low battery is also indicated when the Audible Alarm sounds An alternative display shows the Percent of Load that the inverter can handle If the inverter has excessive load OVL will be displayed USB Power Port This USB Power Port provides 5 Volts DC to charge cell phones personal media players and a host of USB powered...

Page 4: ...turn the inverter Off momentarily press Lock If the wireless remote fails to control operation of the inverter you may be out of range for the radio signal move closer to the inverter If the Remote Switch has a depleted battery open the unit by unscrewing the three small screws on the back side of the remote control and replace the 12 volt model 23A alkaline battery with a new one Rear Panel Posit...

Page 5: ... total watt hours of energy needed This is done by multiplying average power consumption in watts by hours of run time For example 500 watts for 10 hours 5000 watt hours To get an estimate of the maximum current in amps that a battery bank must be capable of delivering to the inverter divide the load watts by ten For example a 500 watt appliance load Load Considerations When an appliance with a mo...

Page 6: ...tage This means that the output voltage of a nominal 12 volt battery starts at 13 4 volts fully charged then drops to 10 5 volts discharged If the load on the battery causes the battery to discharge faster than the 20 hour rate the capacity AH of the battery is measurably reduced derated In heavy battery discharge applications double the estimated Amp Hour rating and configure batteries to support...

Page 7: ... to the chassis of your vehicle or to the grounding system in your boat In a city the ground wire can connect to a metal cold water pipe that goes underground In remote locations the ground wire can be connected to an earth ground This can be an attachment to a foot long copper clad metal rod driven into the ground In the unlikely event of a short circuit operating the inverter without proper grou...

Page 8: ... the inverter system is used during commercial power outages that occur daily configure the charger system to replace energy during the time that commercial power is available Replacement of battery energy always requires more than was taken from the battery typically 30 percent more Follow battery manufacturer s recommendations for maximum charging current WARNING There is danger of explosion DO ...

Page 9: ...ous power output Unit may be defective See warranty and call customer service PROBLEM Inverter Shut Down Fault LED Lit OVL Display Reason Solution Equipment being operated draws too much power Use a higher capacity inverter or do not use this equipment PROBLEM Continuous Buzzing Sound Display Shows Low Voltage Reason Solution Input voltage below 10 5 Volts Keep input voltage above 10 5 Volts Poor ...

Page 10: ...rsonnel or other causes not arising out of defects in materials or workmanship This warranty is effective only if the product is purchased and operated in the USA and does not extend to any units which have been used in violation of written instructions furnished Warranty Disclaimers This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to as...

Page 11: ...stomerservice wagan com Toll Free 1 800 231 5806 31088 San Clemente Street Hayward CA 94544 U S A 2010 Wagan Corporation All Rights Reserved Wagan and wagan com are trademarks used by Wagan Corporation Revised June2010 ...

Reviews: