background image

Cordless Spotlight Compressor

 by Wagan Tech

®

5

www.wagan.com

©2013 Wagan Corporation. All Rights Reserved.

Wagan Tech and 

wagan.com 

are trademarks used by Wagan Corporation.

User’s Manual—Read before using this equipment

6

3.  Set the compressor on/off switch to “ON” by changing from 

position “O” to “—”. 

4.  Monitor pressure on air pressure gauge. 
5.  When desired pressure is reached, turn off the compressor.
6.  Turn the locking thumb lever to up position and remove stem 

connector from valve stem. Also remove the valve stem adapter. 

7.  Store the compressor hose in its storage compartment.

Note:

 In the event that the tire is completely flat, raise the vehicle 

using a recommended jack before inflating the tire.

B.  To Inflate Plastic Inflatable Products 

(recreational balls, air mattresses, rubber rafts, etc.): 

1.  Check manufacturer’s specification on item to be inflated for 

correct inflation pressure. 

2.  Open the air hose storage compartment (lifting up the spotlight 

lantern) and extend the air hose.

3.  Make sure locking thumb lever is at up position. If necessary, use 

valve stem adapter. Insert stem connector to valve stem and press 

down the locking thumb lever to engage. Make sure connector is 

pushed to valve stem as far as possible. 

4.  Insert other end of valve stem adapter into inflatable air valve stem 

as far as practical. 

5.  Set the compressor on/off switch to “ON” by changing from 

position “O” to “—”. 

6.  Monitor pressure on air pressure gauge. 
7.  When desired pressure is reached, turn off the compressor.

8.  Turn the locking thumb lever to up position and remove stem 

connector from valve stem. Also remove the valve stem adapter. 

9.  Store the compressor hose in its storage compartment.

Using the Jumper

IMPORTANT: Before attempting to start vehicle, this unit must be removed 

from the vehicle’s 12 V socket.

1.  Turn off all lights and all other accessories (radio, etc) in the vehicle. 

Tip: keep one small vehicle light or dial turned on to aid in determining 

if the battery is charging.

2.  Make sure the vehicle’s 12 V Socket is clean and free of debris. 
3.  Put the lighted end of the male-to-male car power cord into the 

vehicle’s 12 V socket. 

4.  Put the end of the male-to-male 12 v car power card with no LED light 

into unit’s 12 V socket. 

5.  The indicator light on the 12 V connector will illuminate indicating 

that the power is flowing. The light or dial left on in the vehicle should 

brighten as well. Leave the unit connected to the vehicle’s 12 V socket 

for about 35 minutes. 

6.  If the light or dial does not brighten, turn the ignition key ONLY as 

far as the accessory position (see vehicle owner’s manual.) In some 

vehicles, this is necessary for the 12 V socket to operate. 

7.  If the light or dial still does not brighten, turn off the light or dial, and 

allow this unit to remain on the 12 V socket for at least 35 minutes. 

Remove it from the 12 V and attempt to start the vehicle. 

8.  If the vehicle does not start, DO NOT attempt to start the engine more 

that twice. Call a service center or tow truck.

Summary of Contents for Cordless Spotlight Compressor

Page 1: ...Item Art culo 2450 Cordless Spotlight Compressor with Emergency Car Starter con Encendedor de autos para emergencias User s Manual Manual de Usuario...

Page 2: ...r gauge Recharge and start an auto battery in minutes Super bright adjustable angle flashlight 3 LED reading light Use as a power source for many electronic appliances GENERAL SAFETY RULES KEEP THIS P...

Page 3: ...Recharging the unit for more details Before attempting to start a vehicle this unit must be removed from the vehicle s 12 V socket See the section Using the Jumper for details The unit is designed to...

Page 4: ...onitor pressure on air pressure gauge 7 When desired pressure is reached turn off the compressor 8 Turn the locking thumb lever to up position and remove stem connector from valve stem Also remove the...

Page 5: ...dle of the unit Change it from O to I position B LED Reading light locate the on off switch on the handle of the unit Change it from O to II position Note The halogen and LED bulbs are not designed to...

Page 6: ...Authorization number RMA and return instructions Each item returned will require a separate RMA After you have received the RMA and the return instructions from WAGAN Corporation please follow the ins...

Page 7: ...os Linterna de hal geno con ngulo ajustable Luz de la lectura con 3 LEDs Fuente de energ a para aparatos electr nicos REGLAS GENERALES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES PARA REFERENCIAS FUTURAS...

Page 8: ...l agua y de otros l quidos No utilice este producto si alguno de los a lambres esta roto o si el producto no est trabajando correctamente Desconecte el producto cuando no este en uso REGLAS ESPEC FICA...

Page 9: ...esi n mientras que infla el neum tico 6 Cuando alcance la presi n adecuada para el neum tico apague el compresor 7 Desconecte la manguera y cierre el casquillo de la v lvula 8 Almacene la manguera en...

Page 10: ...da en el veh culo aun no se iluminan apague la peque a luz en el veh culo y deje esta unidad conectada al z calo de 12 V por aproximadamente 35 minutos 9 Despu s de 35 minutos desconecte el compresor...

Page 11: ...argando con una fuente de corriente CA 1 Conecte el alambre cargador CA en el z calo de carga de la unidad 2 Conecte el otro extremo del cargador en cualquier z calo de corriente de casa Deje la unida...

Page 12: ...s y env e el art culo con ENV O PREPAGO junto con la documentaci n solicitada una explicaci n completa del problema su nombre direcci n y n mero telef nico para ponerse en contacto durante el d a WAGA...

Page 13: ...231 5806 customerservice wagan com www wagan com 2013 Wagan Corporation All Rights Reserved Wagan Tech and wagan com are trademarks used by Wagan Corporation Corporaci n Wagan 2013 Todos los derechos...

Reviews: