![background image](http://html.mh-extra.com/html/wagan/7010/7010_user-manual_867510010.webp)
3-in-1 Electric Jack, Impact Wrench & Air Compressor by Wagan Tech
®
9
www.wagan.com
TROUBLESHOOTING
Jack is not working:
1. Check whether the vehicle power is on.
2. Check whether the function switch is in the correct function position.
3. Check if the indicator LED for the cigarette lighter plug is lit or not. If not,
please re-connect the plug. If after re-connecting, it is still not lit, please
check whether the internal fuse of the cigarette lighter plug is destroyed.
4. Check whether the plug connecting the power cable and the jack is loose
from the jack or disconnected.
5. If the socket is not powered, check whether the plug connecting the power
cable and the 12V DC plug is loose. Please connect the power correctly.
If the power switch is in the position of "O", please move the switch to
"I" (See Diagram Three). Check whether the cigarette lighter plug fuse is
broken, if it is, please replace it, then try again.
Not Inflating:
1. Check whether the inflator pump will start.
2. Check whether the nozzle of air hose is correctly connected to the tire air
nozzle.
3. Inspect the air hose to see if it is leaking air.