FRONT PANEL
The Front Panel view shows the inverter’s On/OFF Switch, indicators, AC outlets and direct wiring
high current terminals.
1. ON/OFF Switch
This switch controls ON/OFF operation of the inverter.
2. Over Heat Indicator
The Over Temperature LED will turn RED and the inverter will automatically shut down if the
inverter shuts down because of inadequate ventilation or excessive load. If this occurs, turn
OFF the inverter and check that the ventilation openings are not blocked. Then check that the
continuous power requirement of the appliance load does not exceed 8,000 watts. After the shut
down condition is removed, turn on the inverter. When the inverter cools to a safe temperature, it
will automatically restart.
3. Over Load Indicator
This indicator turns RED as the inverter shuts down. Immediately turn off some appliances if this
occurs. The inverter will automatically restart.
4. Bar Graph Meters
The inverter is equipped with digital bar meters that display DC input voltage and DC current
drawn to indicate system operation. These meters are there to assist diagnosis if there are DC
power supply problems.
DC voltage reading is the measurement of the voltage between the DC input terminals of the
inverter, not the actual battery voltage. During high wattage applications the display may show a