background image

WAFER  GSM-DKEY  REMOTE  CONTROL  UNIT 

http://www.waferstar.com 

#PWD123456#OUT2=ON or OFF  

(If has the second relay output on board) 

You will receive the following confirmation SMS: OUT2 ON OK or OUT2 OFF OK 

 
#RLY Toggle the Relay temporarily ON or OFF for specified timer  (PC$PHONE) 

#PWD123456#RLY1=5 
You will receive the following confirmation SMS: #RLY1-ON: 05 
#PWD123456#RLY2=12  
You will receive the following confirmation SMS: #RLY2-ON: 12 
 

Config the RELAY Status when power Reset again 

#PWD123456#POWER-RESET=11 (1 means ON ,0 means OFF when power on) 

You will receive the following similar confirmation from the unit 

   

POWER-RESET OK

 

#PWD123456#POWER-SAVE 

You will receive the following similar confirmation from the unit 

   

POWER-SAVE OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for GSM-DKEY

Page 1: ...WAFER GSM DKEY REMOTE CONTROL UNIT http www waferstar com GSM DKEY MANUAL SHANGHAI WAFER MICROELECTRONICS CO LTD...

Page 2: ...there will be no charge at least with today s charging procedures and click the relay momentarily Also GSM DKEY has two alarm input port for the security detection including the intruder detection al...

Page 3: ...nserting it in the unit otherwise the device will not work In order to do so insert the SIM in a phone and disable the PIN request usually there is a security menu that enables you to do so Please rea...

Page 4: ...PC software to program and inquire the status of the terminal The bellow wire picture is to show how to connect the cable to the PC program connector with the Program adapter Please connect it in the...

Page 5: ...ssword then reply would be Error New Password Please Check the input again WHL White List This is the command that you will use most it is used to add or remove numbers that are enabled to open the ga...

Page 6: ...number would operate from 8 32 to 18 26 from Mar 24th to Oct 12 PWD123456 QHL001 13564121668 12 Acknowledge QHL003 SETUP TO 61143817 12 QHL001 number would operate total 12 times then would be expire...

Page 7: ...th the command PWD123456 GOT PC PHONE Acknowledge GOT1 05S GOT2 052999S ALARM Alarm setup 1 You can setup the alarm phone number when have the alarm information input PWD123456 ALARM01 13818120592 PC...

Page 8: ...t ranges from 0 to 32 if it is 0 we doubt it will ever answer You should have a signal above 12 to be sure of being able to open the gate in any condition Better if above 16 You should add an external...