background image

WAFER  GSM-DKEY  REMOTE  CONTROL  UNIT 

http://www.waferstar.com 

INSTALLATION 

 
 
 
 
 
 
 
 
 
 

 

 
 
To install the GSM-DKEY, you need to connect the 2 wires of the relay contact in parallel 

with the gate opening button. The relay contacts can stand 

48V 0.5A maximum

, this is enough 

for its operation but 

don't try to switch higher voltages or currents

. You should install the 

GSM-DKEY in a place where there is GSM signal coming from the operator you want to use. 
Check it with a phone before proceeding with the installation. If you need to install the device in a 
place with little signal, you may consider using an external antenna that we may supply as an 
option to be purchased separately with 50cm cable. 

You should then insert the SIM Card of the operator you want to use with the right direction 

according to the following pictures. 

!Note! : You must remove the PIN request from the SIM before inserting it in the

 

unit

, otherwise the device will not work. In order to do so, insert the SIM in a phone and 

disable the PIN request (usually there is a security menu that enables you to do so). 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 

Please read this entire manual before installation     

!Note!

 

 

Take EXTREME care with the high voltage AC220V Power line installation 

 

In case of fault pull the mains adapter out from 220V network immediately. 

 

If device is connect into electricity, you couldn’t take off its cover. 

 

To maximise reception, install the GSM antenna in a prominent elevated position 
if possible, and vertically mounted. 

 

The GSM unit requires mounting carefully in a weatherproof enclosure for out 

  door operation. 

 

Always ensure that the power is switched OFF before inserting or removing a SIM 

  card from its holder or damage will be caused to the module.   

 

1.Slide back the SIM door and lift it up 
2.Slide the SIM Card into the SIM door 

making sure that the clipped corner of the 
SIM card lines up with the clipped corner 
of the SIM holder 

3.Close the SIM door 
4.Slide the SIM door to lock the SIM card in 

place 

Summary of Contents for GSM-DKEY

Page 1: ...WAFER GSM DKEY REMOTE CONTROL UNIT http www waferstar com GSM DKEY MANUAL SHANGHAI WAFER MICROELECTRONICS CO LTD...

Page 2: ...there will be no charge at least with today s charging procedures and click the relay momentarily Also GSM DKEY has two alarm input port for the security detection including the intruder detection al...

Page 3: ...nserting it in the unit otherwise the device will not work In order to do so insert the SIM in a phone and disable the PIN request usually there is a security menu that enables you to do so Please rea...

Page 4: ...PC software to program and inquire the status of the terminal The bellow wire picture is to show how to connect the cable to the PC program connector with the Program adapter Please connect it in the...

Page 5: ...ssword then reply would be Error New Password Please Check the input again WHL White List This is the command that you will use most it is used to add or remove numbers that are enabled to open the ga...

Page 6: ...number would operate from 8 32 to 18 26 from Mar 24th to Oct 12 PWD123456 QHL001 13564121668 12 Acknowledge QHL003 SETUP TO 61143817 12 QHL001 number would operate total 12 times then would be expire...

Page 7: ...th the command PWD123456 GOT PC PHONE Acknowledge GOT1 05S GOT2 052999S ALARM Alarm setup 1 You can setup the alarm phone number when have the alarm information input PWD123456 ALARM01 13818120592 PC...

Page 8: ...t ranges from 0 to 32 if it is 0 we doubt it will ever answer You should have a signal above 12 to be sure of being able to open the gate in any condition Better if above 16 You should add an external...

Page 9: ...mer PC PHONE PWD123456 RLY1 5 You will receive the following confirmation SMS RLY1 ON 05 PWD123456 RLY2 12 You will receive the following confirmation SMS RLY2 ON 12 Config the RELAY Status when power...

Page 10: ...CU LED is not flash slowly MCU is not working properly Check the syster power No tone can be heard after line off hook Check the telephone line connection GSM DKEY is not initialized properly upon sta...

Page 11: ...overview of the products and services of WEIFU GSM Modules For further information and queries kindly contact Email coinco_cn yahoo com cn Web www waferstar com Tel 0086 21 51870528 Also accessible vi...