Connecting the inverter
49
Set grounding bridge
➤
Unscrew the four fastening screws (fig.
9
2, page 7) from the back side
of the device with the included hexagon socket wrench.
➤
Take off the hood (fig.
9
1, page 7).
➤
Unscrew the grounding screw (fig.
9
4, page 7).
➤
Screw the screw into the pre-drilled hole to the left (fig.
9
3, page 7).
➤
Replace the hood of the device and tighten the screws.
10.6
Install external switch to turn device on and off
I
NOTE
Connect the external switch to the inverter using a connection ca-
ble with Western telephone jack. Observe the PIN configuration on
the plug for the connection cable.
➤
Cut a connection cable to size according to the following circuit diagrams:
– external switch, voltage supply from the inverter: fig.
a
, page 9
– Control unit with relay or transistor circuit (TR): fig.
b
, page 9
– external switch with voltage supply from the battery (BAT) of the vehi-
cle: fig.
c
, page 9
– external switch with its own voltage supply (DC POWER) e.g. from the
ignition: fig.
d
, page 9
➤
Connect the external on/off switch with the connection cable on the
remote port (fig.
3
7, page 4).
10.7
Connecting the remote control (accessory)
A
NOTICE! Risk of damage!
Attach the connection to the remote control
only in the Remote-
Port II
and not in the Remote-Port I. False connections can dam-
age the device!
Ensure that the remote control and inverter require the same input
voltage!
➤
Connect the remote control (accessory) to the Remote Port II (fig.
3
6,
page 4).