Installation
IU0U automatic charger
38
Settings for charging voltage for 925-024TB, 925-024TC, 915-024TB, 915-
024TC and 908-024TA:
Settings for the limitation of the period of the main charging phase:
Mute function
If the mute function is switched on, then the unit is operated without active
cooler. Thereby the noise development decreases and the charging capacity
is reduced.
➤
Switch the mute function of the unit ON and OFF with the switch at the
front (see figure 1-9, pos. 1, page 3-5).
5.2
Connecting the IU0U automatic charger
Battery
Warning!
Absolutely avoid contact with the battery fluid!
Caution!
Batteries with cell connection may not be charged, since explosive
gases could occur by overheating the battery.
Charging
voltage
Switch 1
Switch 2
Application range
27,6 V
OFF
OFF
Old starter batteries,
mains charger operation
28,8 V
ON
OFF
Wet and gel batteries
29,6 V
OFF
ON
Fleece batteries
Time limitation of
the main charging
phase
Switch 3
Switch 4
Application range
4 hrs.
OFF
ON
Wet batteries
8 hrs.
ON
OFF
Gel and fleece batteries
No timer function
OFF
OFF
-
_900_serie.book Seite 38 Mittwoch, 22. März 2006 4:28 16