When used on boats the cooling device can be subjected to a constant incli-
nation of 30°.
CoolMatic CB-36, CB-40 and CB-110 devices are equipped with a remova-
ble cooling unit that can be mounted separately.
6
Installing and connecting the cooling
device
6.1
Installing the cooling device
The device is designed for ambient temperatures between –10 °C and
+32 °C. In continuous operation, the air humidity may not exceed 90 %.
Install the cooling device in a dry, sheltered place (installation dimensions:
fig.
1
to fig.
4
, page 4). Avoid installing the devices next to heat sources
such as heaters, gas ovens, hot water pipes, etc.
The cooling device must be installed so that heated air from the cooling unit
can dissipate easily. Therefore make sure there is adequate ventilation.
On the CoolMatic CB-36, CB-40, CB-110 and RHD-50 devices, the cooling
unit is removable and can be mounted at a distance of
z
up to 1.5 m (CB-36, CB-40, RHD-50)
z
up to 2.5 m (CB-110)
away from the cooler if space is limited.
6.2
Adapting the decor (only CB-36, CB-40, CB-110)
The lids of the devices can be adapted to match the decor of the surround-
ings.
6.3
Connecting the cooling device
Connecting to a battery
The cooling device can be operated with a 12 V to 24 V DC voltage supply.
e
Caution!
To avoid voltage loss and therefore a drop in performance, the ca-
ble should be kept as short as possible and should not be interrupt-
ed if this is possible.
For this reason avoid additional switches, plugs or power strips.