Disposal
CombiCool
30
10
Disposal
➤
If possible, always take the packaging material for recycling.
If you wish to scrap the device, ask your local recycling centre or
specialist dealer for details about how to do this in accordance
with the applicable disposal regulations.
11
Technical data
Versions, technical modifications and delivery options reserved.
CAB-40B
CAB-40
CAB-55
Item number (30 mbar):
CAB-40B-
PB30
CAB-40-
PB30
CAB-55-
PB30
Item number (50 mbar):
CAB-40B-
PB50
CAB-40-
PB50
CAB-55-
PB50
Capacity:
Approx. 40 l
Approx. 55 l
Dimensions:
See
1
page 3
Gas consumption:
13 g/h
19 g/h
Connection pressure by
country
Category I
3
, liquid gas
50 mbar
30 mbar
28 – 30/37 mbar
D, AU, LU, CH, CZ, HU:
SE, NO, NL, FI, DK:
GB, E, FR, BE, IE, IT, PT:
Connection to 220 V –
240 V
Power consumption:
75 W
100 W
Current consumption:
0.33 A
0.43 A
12 V connection
Power consumption:
75 W
100 W
Current consumption:
6.25 A
8.33 A
Temperature class:
N
Weight:
Approx. 16 kg Approx. 16 kg Approx. 20 kg
Inspection/certification:
cab-40_40B_55.book Seite 30 Mittwoch, 29. August 2007 12:26 12