12. Unscrew the screw (
D
) from the holder, and pull the dryer filter
straight out.
13. Replace the O-rings (
E
). Moisten new O-rings with refrigerant oil
before installing.
14. Insert the new dryer and tighten the screw to max. 15 Nm.
15. Reconnect the power plug.
16. Switch on the unit.
✓
The inverter performs a self-test.
17. Fasten the cover again.