background image

 

WACOM CONFIDENTIAL 

 

6.3 Environmental characteristics 

Item 

Test condition 

Specification 

6.3.1 

Operational 
Environment 

 
The following tests are carried out during operation 
 

(1) high temperature 

40

°

C   

4hrs 

(2) high temperature, high humidity  40

°

C,  80% 

4hrs 

(3) low temperature 

5

°

 

4hrs 

(4) high temperature, low humidity  40

°

C,  30% 

4hrs 

 

 

No malfunction 

6.3.2 

Storage 
Environment 

 

 

After exposing to below environment, pens are left at normal 

temperature and humidity for 1hour before function check. 

 

(1) high temperature, high humidity  60

°

C,  90% 

96hrs 

(2) low temperature 

-10

°

C   

96hrs 

(3) low humidity 

30

°

C,  30% 

96hrs 

 
  No malfunction 

6.3.3 

Temperature/
humidity 
cycle test 

 
After exposing the pens 3 times to the following temperature 
and humidity, left at normal temperature and humidity for 1hour 
before function check. 
The temperature gradient is to be 15

°

C/h 

 
 

 

 
  No malfunction 

6.3.4 

Electrostatic 
discharge test 

 
  Charging volatage 
  (1) contact discharge:  ± 4.0kV 
  (2) air discharge: 

± 8.0kV 

 

 

  No malfunction 

 

 

Drawing No. 

Rev.  Page 

 

A4A-621A002 

10 

 

 

 

 

Rev. 

Contents 

Sign 

Date 

+60

°

C, 95% 

-20

°

1 cycle 

8h          6h       8h        6h 

Summary of Contents for ESP-110-01-5

Page 1: ...and related notes Authorized Signature Printed Name Title Date This information shall only be used for the specific project of the customer No disclosure is permitted to a third party without written...

Page 2: ...2 6 Average power consumption 6 6 2 7 Power supply requirement 6 6 2 8 External terminals 6 6 2 9 Discharge characteristic TBD 7 6 2 10 Operating life 7 6 2 11 ID specification 8 6 2 12 Tip switch av...

Page 3: ...80 no condensation 3 2 Testing environment Test and measurement are carried out under the following environment as long as there is no specific instruction concerning the testing environment Normal t...

Page 4: ...aiwan BSMI The EMC standard is not applicable to the product 9 USA FCC B System EMC test and DoC by customer OptionPen EMC test by Wacom DoC by customer 10 Argentina The EMC standard is not applicable...

Page 5: ...lowing countries do not require RF standard test Australia Canada China Japan New Zealand EU EFTA South Korea USA Argentina Brazil Chile Hong Kong India Israel Malaysia Mexico Philippines Russia Singa...

Page 6: ...mode EDLC voltage less than 0 9 V Shutdown 6 1 5 Returning time from sleep 5 msec 30 6 1 6 Shifting time to sleep Approximately 10 min Pen operation mode changes from active mode to sleep mode when pr...

Page 7: ...harging voltage 2 65 V typ While power is supplied to the recharging terminals of pen the battery is always being recharged 6 2 5 Operating and charging time 15 seconds charging more than 90 min 300 s...

Page 8: ...om Level 3 of charge to shutdown 46 min 46 min From Level 4 of charge to shutdown 13 min 13 min From Level 5 of charge to shutdown 5 min 6 min AES stylus Typical sample measured in the initial state 6...

Page 9: ...r ID has different Serial ID 3 Vendor ID Value Vendor 2 0b00010 Lenovo 4 Serial ID Serial ID consists of following fields and is unique for each Vendor ID A Factory ID 2 bits ID for distinguish of the...

Page 10: ...6 2 12 Tip switch average pressure curve reference Note The equipment used for measurement is prepared by Wacom Co Ltd Above curve shows on a brand new stylus Drawing No Rev Page A4A 621A002 X 9 Rev...

Page 11: ...erature and humidity for 1hour before function check 1 high temperature high humidity 60 C 90 96hrs 2 low temperature 10 C 96hrs 3 low humidity 30 C 30 96hrs No malfunction 6 3 3 Temperature humidity...

Page 12: ...Applied pressure 1 8 N 3 Operating cycle 100 000 times No malfunction 6 4 3 Drop test 1 Height 80 cm 2 Cycle 15 3 Floor surface Iron plate 4 Fall method To drop a sylus in horizontal attitude No malfu...

Page 13: ...stylus tip pressed while the stylus is not in use it will degrade the tip feel 4 Avoid moisture and humid environments If any water enters the stylus or condensation occurs 5 Do not attempt to disass...

Page 14: ...ckwise wearing non slip rubber groves It will open at Approx 2kg force 3 Remove the nib shaft stuck inside after removing the front unit 4 Tighten the front unit counterclockwise 5 Insert a nib slowly...

Page 15: ...e nib pull it out straight holding a nib by tip tweezer 2 Insert the new nib straight from front unit tip Insert it slowly until the nib touches the back Note that inserting the nib slantwise will cau...

Page 16: ...WACOM CONFIDENTIAL 9 Stylus drawing DIMENSION 315 or less 120 or less 6 or less 30 or less 0 5 3 1 0 0 2 0 4 0 7 0 2 TOLERANCES ESP 110 01 5 Drawing No Rev Page A4A 621A002 X 15 Rev Contents Sign Date...

Page 17: ...WACOM CONFIDENTIAL 10 Packing specification 10 1 Product packing Drawing No Rev Page A4A 621A002 X 16 Rev Contents Sign Date...

Page 18: ...WACOM CONFIDENTIAL 11 Rating Label 11 1 Rating label for Pen body Size 38x 8 mm 11 2 Pasting position Drawing No Rev Page A4A 621A002 X 17 Rev Contents Sign Date...

Page 19: ...cation ZH Digit 17 Production year Last digit of production year Digit 18 Production month Jan 1 Sep 9 Oct A Dec C Digit 19 Production day 1st 1 9th 9 10th A 31st Z Do not use I O Q and U Digit 20 23...

Page 20: ...60x30mm Barcode format is CODE128 Size 100x80mm 12 3 Carton label for Wistron Small 3S label TRACE ID Lot number of shipment date Refer to 19 Lot number coding in next page Drawing No Rev Page A4A 62...

Page 21: ...ng on Sunday ex 01 The week containing January 1 Production Day of week The day of the week number of a production date ex 0 Sunday 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday At ES...

Page 22: ...n list Rev Date Description Designed Remarks X Jul 17 2015 Tentative version Nakajima Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Rev X X X X X X X X X X X X X X X Page 16 17 18 19 20 21 Drawing No Page...

Reviews: