SPECIFICATIONS
· Display:
6600 counts, 66 segments analog bar-graph.
· Polarity:
Automatic, (-) negative polarity indication.
· Overrange Indication:
(OL) or (-OL) is displayed.
· Low Battery Indication:
The "
" is displayed when the battery
voltage drops below accurate operating level.
· Measurement Rate:
2.8/sec, nominal. 28/sec, Analog bar-graph.
· Operating Environment:
0°C to 50°C at < 70% R.H.
· Storage Environment:
-20°C to 60°C at < 80% R.H.
· Temperature Coefficient:
0.1 × (specified accuracy) / °C (< 18°C
or > 28°C).
· Auto Power Off:
30 minutes after rotary switch or mode changes.
· Altitude:
6561.7 Feet (2000m)
· Power:
Standard 9-volt battery, NEDA 1604, IEC 6F22, JIS 006P.
· Battery Life:
75 hours typical with carbon-zine battery.
· Jaw Opening Capability:
57mm conductor, 70 × 18mm bus bar.
· Size
(H × W × D)
:
11.1 × 4.3 × 2.1 inches (281 × 108 × 53 mm).
· Weight:
Approx. 20.1 OZ/570g grams (including battery)
Accuracy is given as ±([% of r[number of least significant
digits]) at 18°C to 28°C, with relative humidity up to 70%.
11
2609C.p65
?2009/12/15, 上午 09:15