![Wacker Neuson PV 35A Operator'S Manual Download Page 12](http://html1.mh-extra.com/html/wacker-neuson/pv-35a/pv-35a_operators-manual_3326508012.webp)
PV 35A
Operation
wc_tx000754gb.fm
12
3.
Operation
3.1
Application
This machine is intended for on-site vibration of concrete for
foundations, walls, columns, slab work, etc. The self-contained design
allows free movement about the jobsite without the restrictions of an
electrical cord.
3.2
Recommended Fuel
The engine requires regular grade unleaded gasoline. Use only fresh,
clean gasoline. Gasoline containing water or dirt will damage fuel
system. Consult engine owner’s manual for complete fuel
specifications.
3.3
Starting the Engine
See Graphic: wc_gr004492
3.3.1
If engine is cold, move the choke lever
(a)
to the CLOSED position
(a1)
. If engine is hot, set the choke to the OPEN position
(a2)
.
3.3.2
Press the priming bulb
(b)
repeatedly until fuel can be seen in the clear
plastic fuel return tube
(c)
.
3.3.3
Turn the engine switch to the ON position
(d1)
.
3.3.4
Pull the starter grip
(e)
lightly until you feel resistance, then pull briskly.
Return the starter grip gently.
3.3.5
Gradually open the choke as the engine warms up
(a2)
.
3.3.6
Open the throttle fully to operate equipment. (See “Operating the
Machine” for more information.)
Summary of Contents for PV 35A
Page 1: ...Handheld Gas Vibrator PV 35A OPERATOR S MANUAL 0171882en 002 0708 0 1 7 1 8 8 2 E N...
Page 2: ......
Page 9: ...Safety Information PV 35A wc_si000224gb fm 9 Notes...
Page 10: ...PV 35A Safety Information wc_si000224gb fm 10 2 5 Label Locations wc_gr004853...
Page 17: ...Operation PV 35A wc_tx000754gb fm 17 Notes...
Page 29: ......