PST2/PSTF2 400
Operation
wc_tx000111gb.fm
17
2.6
Electrical Circuit Diagrams
See Graphic: wc_gr006190
If connected to a circuit protected by a fuse, use a time-delay fuse with
this pump.
Ref.
Description
Ref.
Description
1
Capacitor
5
Frame grounding
2
Main coil
6
Ground
3
Auxiliary coil
8
Float switch (normally open
contact)
4
Miniature protector
wc_gr006190
PSTF2 400
PST2 400
W
W (L)
6
5
8
1
3
2
4
R(Br)
R
Y/G
B
L
L
R
R
1
W
W
B
L
3
2
5
4
6
G
G/Y
G/Y
CAUTION