Operation
Grounding the Machine 7.1
55
[en-US] | 02/2023 | 5100065071 | LTV 4L/6L | Operator’s Manual
7
Operation
7.1
Grounding the Machine
wc_gr013762
1
Fig. 28: Grounding connection
External grounding
A ground connection
(1)
is located on the trailer frame.
Function
This ground connection is used for electrically grounding the machine when
necessary to comply with the National Electrical Code and other federal,
state, and local regulations. For grounding requirements in your area, con-
sult with a qualified electrician, electrical inspector, or local agency having ju-
risdiction over electrical compliance.
If the light tower is used at a construction site, there may be additional regu-
lations which must be observed.
Internal grounding
• The exposed, conductive, noncurrent-carrying components that could
become energized (for example, engine, generator housing, control
panel, trailer, tower sections, and light fixtures) are bonded (connected)
to the machine’s frame.
• The grounding wires of the machine’s power outputs (receptacles) are
bonded (connected) to the machine’s frame.
• The neutral of the generator stator winding is bonded (connected) to the
machine’s frame.
7.2
Refueling the Machine
WARNING
Fire and explosion hazard
Fuel and its vapors are extremely flammable and can be explosive. Burning
fuel can cause severe burns.
►
Keep all sources of ignition away from the machine while refueling.
►
Store fuel containers in a well-ventilated area, away from any com-
bustible materials or sources of ignition.
►
Refuel only when the machine is outdoors.
►
Clean up spilled fuel immediately.
►
Do not smoke while refueling.
►
To prevent static electricity buildup when transferring the fuel from the
pump to the container, place the fuel container on the ground. Hold the
hose nozzle firmly against the side of the container while filling it.