![Wacker Neuson IREN Operator'S Manual Download Page 21](http://html1.mh-extra.com/html/wacker-neuson/iren/iren_operators-manual_3240613021.webp)
9 Maintenance
100_0101_mt_0003.fm
21
9
Maintenance
9.1
Qualifications for maintenance work
Qualifications for maintenance work
The maintenance work described in this operator's manual may be performed by
any responsible user unless otherwise stated.
Some maintenance work may only be performed by specially trained personnel or
by the service staff of your Wacker Neuson contact — these are specifically noted.
9.2
Maintenance schedule
Note:
The time intervals mentioned here are reference values for normal opera-
tion. For extreme operation, e.g. continuous use, the service intervals should
be halved.
The vibrator head assembly is filled with oil by the manufacturer and is therefore maintenance-free.
Note:
If the lower part of the vibrator head assembly needs to be replaced, fill it with
sufficient oil. Secure the lower part of the vibrator head assembly according-
ly. Have this work performed by the service department of the Wacker Neu-
son contact partner.
The oil cannot be replaced in the IREN30 vibrator head. The vibrator head assembly must be
replaced by the service department of the Wacker_Neuson contact partner.
WARNING
Improper handling can result in injury or serious material damage.
Read and follow all safety instructions of this operator's manual, see chapter
Safety information
.
WARNING
Improper handling may cause a danger to life by electrocution.
Only a qualified electrician is permitted to open the machine, perform re-
pairs, and perform a subsequent safety check in accordance with applicable
regulations.
Task
Daily be-
fore oper-
ation
Every
100 hrs.
Visual inspection of all parts
for damage.
Check the wear dimensions.