wc_tx003406gb.fm
38
Operation
GP 4000
4.16
Voltage Selector
The voltage selector switch
(a)
allows the generator to operate in either single
(120V) or dual voltage (120/240V) mode.
In single-voltage mode, use only the 120V twist-lock
(b)
and duplex receptacles
(c1
,
c2)
. The full rated power of the generator is shared between the three
receptacles.
In dual voltage mode both the 120V and 120/240V receptacles are powered; lower
watts are available on receptacles
(c1
,
c2
,
b)
. The 120/240V twist-lock receptacle
(d)
should be used in dual mode only. To achieve full power in this receptacle it
should be used alone.
NOTICE:
Never switch the voltage selector switch with the main breaker on! This
can cause arcing and can damage the generator. Turn all tools and appliances off
and place main breaker
(e)
in the OFF position before changing voltage switch
position.
wc_gr010941
a
b
c2
c1
d
e