Maintenance schedule – daily maintenance jobs
9.3
Maintenance schedule – regular intervals
Maintenance jobs
before operation
after operation
Inspect for completeness.
Visual inspection for damage and leaks.
Check engine oil level and top up if necessary.
Check coolant level and top up if necessary.
Check radiator for dirt and clean if necessary.
Check air cleaner.
Clean machine and remote control.
Maintenance jobs
every 125 h
every 250 h
every 500 h
Make sure the screwed connections are firmly in place:
Crossbar
Central lifting point
Hydraulic oil tank
Rubber buffer of the base plate
Check exciter oil level.
Check hydraulic oil level.
Check hydraulic hose lines.*
Check hydraulic oil level on the center pole.
Check rubber buffer.*
Check function of the proximity recognition sensor (remote
control).
Check operation of the emergency shutdown switch.
Lubricate latches of the protective hood
Check central lifting point for damage.
Replace engine oil and oil filter of the drive motor.
Replace fuel filter.*
Check coolant hoses and clamps.*
Check anti-frost layer of radiator
Check the hosepipes and clamps of the air intake system.*
Replace air cleaner cartridge.
If the control lamp lights up, even before reaching the interval.
Replace exciter oil. *
Check the V-belt of the fan – tighten *.
Replace the hydraulic oil filter with air cleaner.*
Check tapped clearance and adjust if necessary. *
*
Have this work done by the service of Wacker Neuson.