Maintenance
T01007GB.fm
48
5.6
Hydraulic control
5.6.1
Check oil level
1. Move centre pole into vertical position.
2. Open filler bore (1).
3. Oil level must coincide with marking (a), top up with hydraulic fluid if
necessary (see Technical Data).
4. Close filler bore..
5.6.2
Venting hydraulic control
1. Remove apron (4) by undoing the screws (3).
2. Move centre pole into vertical position, move shift lever (2) right into
the reverse position, open filler bore.
3. Loosen connecting screw (5).
4. Slowly push the shift lever into forward motion direction until
hydraulic oil emerges bubblefree at the connection screw.
5. Tighten connecting screw, mount apron.
6. If necessary, top up with, seal filler bore.