T00849GB.fm
34
FAULTS
Reverse speed too low
Cause:
- Too little hydraulic oil in the centre pole head.
- Air in hydraulic control.
Remedy: - Top up hydraulic oil.
- Bleed system.
Forward speed too low
Cause:
- Too much oil in centre pole head.
Remedy: - Correct oil level in accordance with mark.
No advance
Cause:
- Mechanical fault.
Remedy: - Contact Wacker service dept.
Loss of hydraulic oil
Cause:
- Leaks, hydraulic hose defective.
Remedy: - Change defective parts.
Note:
Bleed system after every dismantling operation.
Engine does not start
Cause:
- Fuel tank empty.
- Fuel shut-off valve closed.
- Air filter dirty.
- Stop button defective.
- Recoil starter defective.
- Oil alert system has stopped engine.
Remedy: - Fuel up.
- Open.
- Clean.
- Repair.
- Repair.
- Fill up with engine oil.
Summary of Contents for BPU 2540A
Page 1: ...Operator s Manual Vibratory plate BPU 2540A 3050A 3750Ats 0203079en 005 10 2010...