OPERATION
Operation the engine
As the engine warms up, gradually move the choke lever to the OPEN position.
Position the throttle lever for the desired engine speed.
Oil alert system
The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crank-
case. Before the oil level in the crankcase drops below a safe limit, the oil alert system will automatically shut
down the engine (the engine switch will remain in the „I“ position).
Note: If engine does not start check oil level
Forward and reverse motion
The engine speed can be infinitely varied with the throttle control lever (6).
The direction of travel is determined with the operating control handle (7).
Depending on the position of the control handle (7), the vibration plate compacts in forward direction, on the
spot or in reverse direction.
Forwards
On the spot
Reverse