Troubleshooting
22
7.3
Inverter
Malfunction
Cause
Remedy
LED lights red.
- Line voltage interrupted.
- Incorrect line voltage.
Inverter starts automatically as
soon as the correct line voltage
is available (again).
LED flashes red.
Machine defect.
Have the machine repaired. *
* Have these tasks carried out by the service department of your Wacker Neuson representative per-
son.
LED flashes red twice.
Inverter has switched off due to
excess temperature.
1. Allow the inverter to cool
down.
2. Carry out a reset:
Switch the machine off and
on again.
LED flashes red three times (for
a short period).
The Bodyguard
®
has turned off
the machine.
1. Pull out the plug.
2. Eliminate the fault or have it
eliminated. *
3. Insert the plug.
No Bodyguard
®
present.
Have the machine repaired. *