For the most efficient and reliable operation, the humidity should be
between 40 % and 100 % and the temperature between 3 °C and
40 °C.
The moisture meter turns the air dehumidifier on automatically and
turns it automatically back off when the set limit value has been
reached. The control unit (2) turns the defrosting unit automatically on
and off if the operating conditions change. In addition, the machine is
turned off (fan and compressor switch off, control lamp (b) is lit) if a
malfunction occurs or if the machine overheats in a room that is too hot
(Tmax = 40 °C).
Caution
If the room temperature falls below the minimum level (3 °C), the air
dehumidifier does not function. The control lamp (b) will blink.