wc_tx000178gb.fm
36
Maintenance
PG 2A / 3A
5.12
Long-Term Storage
If pump is being stored for more than 30 days:
Do not open priming plug, discharge plug, or cover when pump is hot.
1. After pump has cooled, remove discharge plug from pump housing and drain
out any water left in the housing.
2. Remove pump cover and clean inside of pump housing. Coat inside of pump
with a light film of oil to reduce corrosion. A spray can of oil works well for this.
3. Tape up suction and discharge ports to prevent anything from falling into pump.
4. Change engine oil and follow procedures described in engine manual for engine
storage.
5. Cover pump and engine and store in a clean, dry area.
WARNING