Operation
4.1
Before starting
4.1.1
Make sure once again that the product is of the correct voltage and
frequency rating.
NOTICE
:
Using the product at other than rated voltage and frequency
will not only lower its performance but may damage the product.
Note:
Confirm the rated voltage and frequency on the model
nameplate.
4.1.2
Confirm the wiring, supply voltage, circuit breaker capacity, and motor
insulation resistance.
Reference insulation resistance = 20 MW or greater.
Note:
The reference insulation resistance (20 MW or greater) is the
value when the pump is new or has been repaired. For the reference
value after installation see Maintenance and Inspection.
4.1.3
The setting on the circuit breaker or other overload protector should
be made in accord with the rated current of the pump.
Note:
See
Operating Specifications
for the rated current of the pump.
4.1.4
When powering the pump with a generator, be certain the generator is
sized to supply the required power for the pump and any other
equipment powered by the generator.