Technical Data
PD
wc_td000178gb.fm
14
2.6
Pump—Machines with Wacker Engines
2.7
Sound Measurements—Machines with Wacker Engines
The required sound specification, Paragraph 1.7.4.f of 89/392/EEC
Machinery Directive, is:
•
the guaranteed sound power level (L
WA
) = 96 dB(A).
•
the sound pressure level at operator’s location (L
pA
):
PDT 2 = 78.8, PDT 3 = 82.
These sound values were determined according to ISO 3744 for the
sound power level (L
WA
) and ISO 6081 for the sound pressure level
(L
pA
) at the operator’s location.
Item Number:
PDI/PDT 2
0009489, 0009494
PDI/PDT 3
0009491, 0009492,
0009495
Pump
Dimensions
(L x W x H)
mm
(in.)
1010 x 630 x 570
(40 x 25 x 22.5)
1010 x 745 x 605
(40 x 29.3 x 24)
Operating Weight
kg (lbs.)
52 (114)
61 (133)
*Max. Suction Lift
m (ft.)
7.5 (25)
Max. Discharge Head
m (ft.)
7.5 (25)
Max. Flow Rate
l/m (gpm)
189 (50)
333 (88)
Gear Case Lubrication
oil grade
ml (oz.)
SAE 80W-90
532 (18)
Suction / Discharge Dia.
mm (in.)
50 (2)
75 (3)
Maximum Solid Size
mm (in.)
32 (1.25)
45 (1.75)
* Based on pump operating at sea level. Maximum suction lift will be less at higher altitudes.
Summary of Contents for PDT 2
Page 2: ......
Page 13: ...PD 2 3 Safety Information wc_si000176gb fm 9...
Page 25: ...PD 2A 3A Operation wc_tx000592gb fm 21...
Page 45: ...PD Repair Disassembly Assembly Procedures wc_tx000590gb fm 41 wc_gr003460 a c f b e d a g g...
Page 53: ...PD Repair Disassembly Assembly Procedures wc_tx000590gb fm 49 wc_gr003465 wc_gr003464...
Page 54: ...Disassembly Assembly Procedures PD Repair wc_tx000590gb fm 50...
Page 59: ......