Safety Information
PG Pumps
wc_si000180gb.fm
6
1.3
Service Safety
Poorly maintained equipment can become a safety hazard! In order
for the equipment to operate safely and properly over a long period of
time, periodic maintenance and occasional repairs are necessary.
1.3.1
DO NOT attempt to clean or service the machine while it is running.
Rotating parts can cause severe injury.
1.3.2
DO NOT crank a flooded engine with the spark plug removed on
gasoline-powered engines. Fuel trapped in the cylinder will squirt out
the spark plug opening.
1.3.3
DO NOT test for spark on gasoline-powered engines if the engine is
flooded or the smell of gasoline is present. A stray spark could ignite
the fumes.
1.3.4
DO NOT use gasoline or other types of fuels or flammable solvents to
clean parts, especially in enclosed areas. Fumes from fuels and
solvents can become explosive.
1.3.5
ALWAYS keep the area around the muffler free of debris such as
leaves, paper, cartons, etc. A hot muffler could ignite the debris and
start a fire.
1.3.6
ALWAYS replace worn or damaged components with spare parts
designed and recommended by Wacker Corporation.
1.3.7
ALWAYS disconnect the spark plug on machines equipped with
gasoline engines, before servicing, to avoid accidental start-up.
WARNING
Summary of Contents for 0007659
Page 2: ......
Page 11: ...PG Pumps Safety Information wc_si000180gb fm 7 1 4 Label Locations w c _ g r 0 0 0 8 3 3...
Page 39: ...PG Repair Disassembly Assembly Procedures wc_tx000608gb fm 35 4 9 10 2 3 1 6 5 7 wc_gr003495 8...
Page 47: ...PG Repair Disassembly Assembly Procedures wc_tx000608gb fm 43 8 11 12 9 7 10 6 5 wc_gr003499...
Page 53: ...PG Repair Disassembly Assembly Procedures wc_tx000608gb fm 49 1 wc_gr003501...
Page 54: ...Disassembly Assembly Procedures PG Repair wc_tx000608gb fm 50...
Page 59: ......