PT 6 /...
Operation
wc_tx000261gb.fm
19
4.5.5
If necessary, rotate the discharge elbow to direct water flow in the
desired direction.
4.5.6
Attach the suction hose to the suction port
(d).
Attach the discharge
hoses to the discharge port
(e)
. Check and tighten the clamps and
coupling to make sure the hoses are securely fastened.
A loose connection can create a serious safety hazard should it break
loose while the pump is running.
4.5.7
Attach the suction strainer to the suction hose to prevent large debris
from being pulled into the pump.
4.5.8
Prime the pump. To do so, open the cover
(c)
at the top of the pump
and fill the pump housing with water. The pump will not prime unless
this is done.
WARNING
wc_gr001165
a
b
f
c
d
e
g
Summary of Contents for 0007174