Installation 

5.1   Mechanical Installation 

5.1.1  Mounting on the DIN rail 

 
The ETHSW50K is equipped with a DIN rail holder on the rear side. Please follow the steps below 
for proper mounting on the DIN rail: 
 

1. 

Tilt the module backwards with the top and press it onto the DIN rail. Align the 
module straight. 

2. 

Press the module down on the DIN rail until it is properly fixed on the rail. Then close 
the lock on the underside by moving it upwards. The lock is correctly performed when 
you hear and perceive a click. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

Note: 

If the fixing clip has come loose from the holder, it must be reassembled as follows. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2

Summary of Contents for ETHSW50K

Page 1: ...endorff de www wachendorff prozesstechnik de Copyright by Wachendorff Prozesstechnik GmbH Co KG Industriestra e 7 D 65366 Geisenheim Germany Tel 49 6722 9965 20 Fax 78 All information is subject to ch...

Page 2: ...llation 6 5 1 Mechanical Installation 6 5 1 1 Mounting on the DIN rail 6 5 2 Electrical Installation 7 5 2 1 Connecting the power supply 7 5 2 2 Connection of the fail safe relay 8 5 2 3 Connecting th...

Page 3: ...conditions on machines and systems Machines and systems must be designed in such a way that faulty states cannot lead to a situation that is dangerous for the operating personnel e g by independent l...

Page 4: ...l Duplex and Back Pressure Half Duplex Interfaces RJ45 Ports copper 5x 10 100BaseT X RJ45 Speed Auto Negotiation 10 100 Mbps RJ45 Duplex Half or Full Duplex RJ45 Connection MDI MDIX Auto Crossover Fau...

Page 5: ...CE EMS IEC61000 4 2 IEC61000 4 3 IEC61000 4 4 IEC61000 4 5 IEC61000 4 6 Level 3 RoHS and WEEE RoHS lead free and WEEE compliant Housing Degree of protection IP30 Execution Robust polycarbonate housing...

Page 6: ...or proper mounting on the DIN rail 1 Tilt the module backwards with the top and press it onto the DIN rail Align the module straight 2 Press the module down on the DIN rail until it is properly fixed...

Page 7: ...ide a suitable 12 to 58 VDC power source and connect it by tightening the screws to the 6 pole terminal plug at the terminals provided for this purpose o P1 Primary power supply o P2 Secondary power s...

Page 8: ...ssage contact Power Alarm at PIN 1 of the DIP switch ON A L M P1 P2 Clamp ALM ALM DIP PIN 1 Signal Connection to alarm system Connection to alarm system ON 5 2 3 Connecting the network devices The ETH...

Page 9: ...thernet link established link up data transmission Off Ethernet link not established link down RJ 45 Ports Port 1 to 5 Speed On yellow Ethernet link with 100 Mbit s established Off Ethernet link with...

Page 10: ...ation Instructions 10 Stand 24 05 2019 8 PIN assignment of the network connection RJ 45 to RJ 45 straight through cable PIN 1 2 3 4 5 6 7 8 Signal Tx Tx Rx Rx RJ 45 cross over cable PIN 1 2 3 4 5 6 7...

Page 11: ...Operating and Installation Instructions 11 Stand 24 05 2019 9 Dimensions of the ETHSW50K series in mm 25 00 113 00 4 50 7 33 90 05 97 38...

Page 12: ...onditions 1 This equipment may not cause harmful interference which can cause harmful interference to radio or television reception 2 This device must accept any interference received including interf...

Reviews: