background image

INSTALLATION INSTRUCTION 

InvisiLED Tunable White  

T24-TW3 

 

Waclighting.com 

Phone (800) 526.2588 

Fax       (800) 526.2585 

Headquarters/Eastern Distribution Center    

44 Harbor Park Drive  

Port Washington, NY 11050 

 

Central Distribution Center  

1600 Distribution Ct  

Lithia Springs, GA 30122  

Western Distribution Center 

1750 Archibald Ave  

Ontario, CA 91761  

 

 

  WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program

.                        Oct. 2022      

5. 

 

 

 

In order to maintain a voltage or having less voltage drop on the tape, bigger conductor wire or lower gauge wire number is recommended. 

 

     

FIG. 9 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    

FIG. 10 

 

0

10

20

30

40

50

60

70

80

90

100

110

15

16

17

18

19

20

21

22

23

24

Re

lati

ve

 P

er

ce

ntag

e of 

Lig

ht O

utp

ut 

Tape Voltage (VDC)

Linear Tunable White

Summary of Contents for InvisiLED T24-TW3

Page 1: ...closer than 6 in from any curtain or similar combustible material Do not modify or disassemble product beyond instructions or warranty will be void Failure to follow safety warnings and installation...

Page 2: ...TE BLACK BLACK BLACK FIG 3 Option B Shielded data Cable 90 ft maximum distance between power supply to the beginning of the tape A shield data cable shall be used to connect between the power supply W...

Page 3: ...e Black 4 To extend an unshielded cable length if needed In Wall Rated Joiner Cable T24 IC and Joiner Cable Extender T24 FF WT can be used to join between sections as shown in FIG 6 FIG 6 5 To extend...

Page 4: ...2300 0 2105 4 83 19 270 123 255 2400 0 1818 4 33 22 240 75 255 2500 0 1667 3 86 24 212 35 255 2600 0 1538 3 58 26 196 13 255 2700 0 1429 3 37 28 183 255 0 2800 0 1538 3 57 26 198 255 12 2900 0 1600 3...

Page 5: ...ution Center 1750 Archibald Ave Ontario CA 91761 WAC Lighting retains the right to modify the design of our products at any time as part of the company s continuous improvement program Oct 2022 5 In o...

Page 6: ...0 64 0 73 0 82 0 91 1 00 1 09 1 18 1 27 1 36 1 45 1 54 1 63 1 72 1 81 3200K 0 09 0 09 0 18 0 27 0 36 0 46 0 55 0 64 0 73 0 82 0 91 1 00 1 09 1 18 1 28 1 37 1 46 1 55 1 64 1 73 1 82 3300K 0 09 0 09 0 1...

Page 7: ...inch interval The cut line is shown on both sides of connector See FIG 11 FIG 11 9 Mount InvisiLED Tunable White tape light clean surface before mounting Peel off 3M VHB adhesive backing covers off as...

Page 8: ...022 8 Tape to Tape T Connector T24 TI WT See FIG 14 Tape to Tape X Connector T24 XI WT See FIG 15 FIG 14 FIG 15 1 Tape to Tape L Connector T24 LI WT See FIG 16 Flex Tape to Tape Y Connector T24 Y WT S...

Page 9: ...750 Archibald Ave Ontario CA 91761 WAC Lighting retains the right to modify the design of our products at any time as part of the company s continuous improvement program Oct 2022 9 SYSTEM DIAGRAM Inv...

Page 10: ...less voltage drop and boost light output up Another way is to lower a maximum DMX value to reduce the current consumption to InvisiLED TUNABLE WHITE tape Thus a contrast between beginning and the end...