3. 

 

 

 

 

 

 

    

  

 

 

Hard Wire:  

  Enclosed 24VDC Dim-To-Warm class 2 output remote power supply must be installed away from any 

heat sources and it must be accessible for service.  

  Enclosed 24VDC Dim-To-Warm class 2 output remote power supply is UL listed.  

  The power supply box has a separate line voltage, and low voltage wiring compartments.  

  Trade size knock out are provided on both compartments. Connect building wires to the same color power 

supply wires with wire nuts or UL certified electrical connector.  

  Building ground wire may be green or uninsulated, and attaches to green wire from power supply box. 

  Additional power feeds and wiring components are available.  

 

 

 

4. 

Slide the switch position to set low end desirable color temperature (CCT) on the power supply

 

  Low end CCT can be adjusted and selected among 1800K, 1900K, 2000K, 2100K, 2200K. 

 

 

 

Summary of Contents for AiSPiRE A2D50-60

Page 1: ...r to installation to prevent electrical shock For installation and serviced by a qualified licensed electrician Install in accordance with national electric code and local regulations Consult with local inspector to assure compliance CAUTION Read all instructions before installing Handle product with care Do not modify or disassemble product beyond instructions or warranty will be void Failure to ...

Page 2: ...f the tape run and make sure that it is under 100ft The allowed maximum distance of wires between the output of power supply to the beginning of tape is 100 ft The minimum output gauge wire of power supply is 20 AWG To extend the cable length if needed In Wall Rated Joiner Cable A2L02 and Joiner Cable Extender A2L01 WT can be used to join between sections as shown below To extend the cable length ...

Page 3: ...e power supply must be installed away from any heat sources and it must be accessible for service Enclosed 24VDC Dim To Warm class 2 output remote power supply is UL listed The power supply box has a separate line voltage and low voltage wiring compartments Trade size knock out are provided on both compartments Connect building wires to the same color power supply wires with wire nuts or UL certif...

Page 4: ...prings GA 30122 Western Distribution Center 1750 Archibald Ave Ontario CA 91761 AiSPiRE retains the right to modify the design of our products at any time as part of the company s continuous improvement program March 2022 4 SYSTEM DIAGRAM ON OFF Switch System ELV Dimmer Control System 0 10V Dimmer Control System CAUTION AISPIRE Dim To Warm Tape light may not be able to dim with other power supply ...

Reviews: