INSTALLATION INSTRUCTION
24VDC Dim-To-Warm POWER SUPPLY
A2D50-60, A2D50-96
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Ave
Ontario, CA 91761
AiSPiRE retains the right to modify the design of our products at any time as part of the company's continuous improvement program
. March 2022
3.
Hard Wire:
•
Enclosed 24VDC Dim-To-Warm class 2 output remote power supply must be installed away from any
heat sources and it must be accessible for service.
•
Enclosed 24VDC Dim-To-Warm class 2 output remote power supply is UL listed.
•
The power supply box has a separate line voltage, and low voltage wiring compartments.
•
Trade size knock out are provided on both compartments. Connect building wires to the same color power
supply wires with wire nuts or UL certified electrical connector.
•
Building ground wire may be green or uninsulated, and attaches to green wire from power supply box.
•
Additional power feeds and wiring components are available.
4.
Slide the switch position to set low end desirable color temperature (CCT) on the power supply
•
Low end CCT can be adjusted and selected among 1800K, 1900K, 2000K, 2100K, 2200K.