WIRING AND INSTALLATION:
1. Turn Power off at circuit breaker
2.
Mounting
Enclosed 24VDC CCT class 2 output remote power supply at desired location. Measured a distance
between power supply to the beginning of the tape run and make sure that it is under 100ft.The allowed
maximum distance of wires between the output of power supply to the beginning of tape is 100 ft. The
minimum output gauge wire of power supply is 20 AWG.
To extend the cable length (if needed), In Wall Rated Joiner Cable (T24-IC) and Joiner Cable Extender (T24-
FF-WT) can be used to join between sections as shown below:
To extend the cable length between power supply cable or a wiring box to a tape sections, (if needed), In Wall
Rated Extension Cable (T24-EX3) can be used to join between sections by soldering as shown below:
Wire Color
CCT Power Supply Output
T24-EX3 Cable
Tape marking
RED
RED
+24VDC
BLACK
BLACK
-5000K
BLUE
WHITE
-2700K
T24-FF-WT
T24-IC
T24-FF-WT
T24-EX3
100 ft. Max