WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MAy 31, 2016 10:13 AM
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
2
FEATURES AND CONTROLS:
1.
Take-apart stainless cover
The cover can be removed for greater access to wiring compartment during installation.
To remove, open the cover by unscrewing the four screws from the sides.
2.
Operating instructions on the cover
Refer to these instructions for additional information on specifications of the product
3.
Overload circuit breakers
For reliable automatic secondary circuit protection. Circuit breakers may also be used as on/off rocker switches.
4.
1/2” – 3/4” Knockouts
For conduit and accessory mounting
5.
1/2” – 3/4” Knockouts
For conduit and accessory mounting
6.
Terminal strip
For multiple low voltage cable connections
7.
Power cord
Heavy-gauge, grounded, water-resistant power cord with integrally molded plug.
8.
120-volt timer module receptacle
For use with optional, removable multi-setting mechanical 24-hour timer or electronic/digital 7-day timer.
9.
Photocell plug
For use with photocell, remove jumper and plug photocell here.
10.
Locking Hole (for model 9150-TRN-SS and 9300-TRN-SS)
Can be secured to prevent tampering
11.
Conduit cover (for model 9150-TRN-SS and 9300-TRN-SS)
Remove the conduit cover and use Trade Size 1-1/4 inch conduit
INSTALLATION INSTRUCTION
Magnetic Transformer
9075-TRN-SS / 9150-TRN-SS / 9300-TRN-SS
10
11
=
use looped wire to test
primary amps under full load
N
R
s
N
Q
s
N
P
s
N
O
s
`
l
j
SUITABLE FOR WET LOCATION
LOW VOLTAGE LANDSCAPE POWER SUPPLY
MADE IN CHINA
DC-2015-11-06
MODEL:JCOBS12D75B1-1-PI
INPUT:120V 60HZ 0.625A
OUTPUT:12V-13V-14V-15V
MAX.RATING:75W 6.25A
`
l
s
b
o
=
=
j
r
p
q
=
=
_
b
=
=
f
k
p
q
^
i
i
b
a
j
l
r
k
q
=
q
e
f
p
=
r
k
f
q
=
k
l
=
i
b
p
p
=
q
e
^
k
=
N
=
c
l
l
q
=
^
_
l
s
b
=
d
o
l
r
k
a
=
i
b
s
b
i
=
t
f
q
e
=
^
o
o
l
t
p
m
l
f
k
q
b
a
=
r
m
ISOLATED WINDING TYPE TRANSFORMER
CIRCUIT INTERRUPTER OUTLET LOCATED AT LEAST 10FT
THIS UNIT IS EQUIPPED WITH A THERMAL PROTECTOR
BREAKER TRIPS CHECK TOTAL WATTAGE OF LAMPS OR FOR A SHORT
IN THE CIRCUIT
PLUG PHOTOCELL
HERE
(CREMOVE JUMPER)
PHOTOCELL PLUG
TIMER MODULE
RECEPTACLE
l
c
c
l
k
1
2
3
4
5
6
7
8