51
www.nieaf-smitt.com
Function
Range
Resolution
Accuracy
Duty cycle
0.1 % ~99.9 %
0.1 %
+ (1.2 % + 2 d)
Pulse width: >100 us, <100 ms
Frequency width: 5 Hz–150 kHz
Sensitivity: <0.5 V RMS
Overload protection: 1000 VDC or AC rms
Function
Test current
Resolution
Accuracy
Diode test
0.3 mA typical
1 mV
+ (10 % + 5 d)
Open circuit voltage: Max. 1.5 VDC
Overload protection: 1000 VDC or AC rms
Audible threshold
Less than 150
Ω
test current max. 0.3 mA
Overload protection
1000 VDC or AC rms
Display
4.000 count backlit liquid crystal with bargraph
Overrange indication
‘
OL’ is displayed
Auto Power OFf
15 min approx. with disable function
Polarity
Automatic (no indication for positive); minus (-) sign for
negative
Measurement rate
2 times per second, nominal
Low battery indication
BAT appears if battery voltage drops below operating
voltage
Battery
1x 9 V battery
Operating temperature
0 ºC...+50 ºC (+32 ºF...+122 ºF) @ < 70 & RH
Storage temperature
-20 ºC...+60 ºC (-4 ºF...+140 ºF) @ < 80 & RH
Operating altitude
2000 meter (7000 feet)
Weight
255g
Dimensions
150 x 70 x 48 mm
Safety
This meter is intended for origin of installation use and
protected, against the users, by double insulation per
EN61010-1 to Category IV 600 V and Category III 1000V;
Pollution Degree 2.
The meter also meets UL 61010-1, 2 Edition (2004), CAN/
CSA C22.2 No. 61010-1 2 Edition (2004), and UL 61010B-
2-031, 1 Edition (2003)
Environmental specifications
Warranty
Wabtec Netherlands B.V. guarantees the tester for a period of 12 months. The
period of warranty will be effective at the day of delivery. The warranty clauses
and the stipulations regarding liability in terms of delivery (FME and HE).