22
www.nieaf-smitt.com
Clamp size
Opening 30 mm (1.2”) approx.
Diode test
Test current 0.3 mA typical,
open circuit voltage 3 VDC typical
Continuity check
Threshold <50
Ω
, test current < 0.5 mA
Low battery indication
‘ ‘ is displayed
Overrange indication
‘OL‘ is displayed
Measurements rate
2 per second, nominal
Input impedance
10 M
Ω
(VDC and VAC)
Display
4000 counts LCD
AC current
True RMS 50...60 Hz (AAC)
AC voltage
50...400 Hz (VAC)
Operating temperature
+5
o
C...+40
o
C (+40
o
F...+104
o
F)
Storage temperature
-20
o
C...+60
o
C (-4
o
F...+1404
o
F)
Operating humidity
Max. 80 % up to 31
o
C (87
o
F) decreasing
linearly to 50 % at 40
o
C (104
o
F)
Storage humidity
< 80 %
Operating altitude
2000 m (7000 ft)
Over voltage
CAT III, 600 V
Battery
2xAAA batteries
Auto OFF
Approx. 30 min
Dimensions
198 x 66 x 36 mm
Weight
230 g
Safety
For indoor use and in accordance with
Overvoltage Category II, Pollution Degree
2. Category II includes local level, appliance,
portable equipment, etc., with transient
overvoltages less than Overvoltage Cat. III