Marine Head Manual P/N 24533
12
June 25, 2002
HOPPER REPLACEMENT
Model LF-210 and LF-219 Models Only
CAUTION
:
Read this entire procedure
before beginning work!
1. Remove toilet from floor. Place toilet
upside down on a sheet of cardboard or
other padded material.
2. Remove nuts from J-bolts on either side
of hopper, lift hopper from bowl.
3. Remove o-ring between hopper and seal
adaptor. Check that o-ring is not
damaged, replace if necessary.
4. Re-assemble in reverse order.
MAKE SURE J-BOLTS ARE TIGHT!
Proper torque specification is 4-6
inch/lbs.
Note:
The air cylinder on the hopper sub-assembly should be cleaned, lubricated and checked for adjustment
whenever the toilet assembly is removed for servicing.
TANK ISOLATION VALVE INSTALLATION
(Not supplied with toilet.)
Note:
Check valve halves for tightness before
installing.
Rear Discharge with LF-219 Downward Hose
Install Tank Isolation Valve Assembly in line
at the end of the discharge hose using a 1-1/2"
long pipe nipple.
Rear Discharge
Glue tank isolation valve assembly to hopper at
point indicated.
Bottom Discharge, No Flange
Glue Tank Isolation Valve Assembly directly
to hopper discharge as indicated.
Bottom Discharge with Flange (1-1/2" pipe)
Glue 1/2" long pipe nipple to hopper discharge
port as indicated, and glue Tank Isolation
Valve assembly to pipe nipple.
NOTE: Isolation Valve is in two pieces;
tighten valve before installation and
again before making drain connection!