WABCO MICO ACV-DMO-RV Product Explanation, Operating Information, And Service Instructions Download Page 3

Form No. 81-463-019      Revised 2017-06-01 

(3)

 

 

          

 

 

 

   MICO, Inc.

TABLE 1 

(Specifications)

Model  

Number

Repair Kit 

Number

Nominal  

High Limit (cut out)

bar             (PSI)

Nominal  

Low Limit (cut in) 

bar             (PSI)

06-463-415 

06-463-424 

06-463-425 

06-463-426 

06-463-432 

06-463-434 

06-463-439 

06-463-440 

06-463-441

06-463-455 

06-463-496

06-400-184 

06-400-184 

06-400-452 

06-400-184 

06-400-184 

06-400-184 

06-400-439 

06-400-228 

06-400-439

06-463-498 

06-400-184

103.4 ± 3.5       (1500 ± 50) 

186.2 ± 3.5       (2700 ± 50) 

175.8 ± 3.5       (2550 ± 50) 

181.0 ± 3.5       (2625 ± 50) 

155.1 ± 3.5       (2250 ± 50) 

127.6 ± 3.5       (1850 ± 50) 

168.9 ± 3.5       (2450 ± 50) 

193.1 ± 3.5       (1850 ± 50) 

127.6 ± 3.5       (1850 ± 50) 

172.4 ± 3.5       (2500 ± 50) 

188.6 ± 3.5       (2735 ± 50)

86.2 ± 3.5        (1250 ± 50) 

155.1 ± 3.5       (2250 ± 50) 

146.5 ± 3.5       (2125 ± 50)  

150.0 ± 3.5       (2175 ± 50) 

125.8 ± 3.5       (1825 ± 50) 

103.4 ± 3.5       (1500 ± 50) 

150.0 ± 3.5       (2175 ± 50) 

137.9 ± 3.5      (2000 ± 50) 

103.4 ± 3.5      (1500 ± 50) 

125.8 ± 3.5       (1825 ± 50) 

140.3 ± 3.5      (2035 ± 50)

NOTE: If your product number is not listed, please contact MICO, Inc. for information.

Items included in Repair Kit

Not used on all models 
Model number 06-463-425 will reuse poppets (34 & 38).

NOTE

Model numbers 06-463-415, 06-463-440, and 

06-463-455 use a ball in place of poppet (28). 

This ball is not included in the repair kit.

FIGURE 1

Figure 1b

Figure 1a

VALVE ADJUSTMENT

(Refer to Table 1)

  1. See machine servicing instructions to properly reinstall accumu-

      lator charging valve. Tee an accurate pressure gauge on an 

      accumulator line.

  2. Start pump and allow approximately one minute for charging to

      start (pressure in gauge will read accumulator precharge plus). 

      If valve does not begin to charge remove plug (8) and turn screw

      (10) in, stopping when gauge shows an increase in pressure.

      Check the high limit specifications (see TABLE 1) and adjust

      screw (10) until the high limit setting is met. Reinstall plug (8).

      This pressure can be checked correctly only if after each adjust-

      ment of screw (10) the accumulator pressure is reduced below

      the low limit setting and the system recharges the accumulator

      pressure to its high limit. Repeat process until high pressure 

      setting is accurately adjusted. 

NOTE: Be sure to reinstall plug 

      (8) before starting pump.

  3. Torque plug (8) 47.5-54.2 N·m (35-40 lb·ft).

Reviews: