© W
&
W 05/2007 Version 13
13
Yellow advice label for parallel mounting:
Glue the yellow advice label on the highest ladder beam,
so that the arrow shows into the right direction.
Choose the right label for your requirements.
Control switch
Install the switch for monitoring the bottom part of the ladder and the fl oor lever mechanics professionally in series to the
emergency-brake-switch in the safety circuit of the lift control system. The switch has a rated operational current of AC15
3A at 250V and DC13 3A at 24V.
Final safety inspection
At the end check again if the distance from the car and the apron to the ladder in folded position is suffi cient when the
buffers are completely compressed and if the travelling cables are not colliding with the ladder.
If some imponderabilities occur while mounting, which get in the way of professional mounting, the operations have to be
cancelled and it is necessary to consult the manufacturer.
W
all where
the ladder is
put up
TRI-KLAPP 95