Page 17 of 34
PQ-132-U
4.5 Typical wiring
4.6 Connection examples
+In PIN 13 oder 14
PIN 12 (GND)
SPS / PLC 0... 10 V Sollwert, Sensor Spannungssignal
+In PIN 9
-In PIN 10
GND PIN 11
AIN:W 2000 1600 2000 C ( für 0... 100%)
+In PIN 13 oder PIN 14
In PIN 12 (GND)
Stromsensor 4... 20 mA in zwei Leitertechnik
z. B. 24 V
+In PIN 13 oder 14
PIN 12 (GND)
AIN:W 2000 1600 2000 C ( für 0... 100%)
Stromsensor 4... 20 mA in drei Leitertechnik
z. B. 24 V
Valve (6 + PE plug) with OBE electronics
A : 24 V supply
B : 0 V supply
C : GND or enable
D : + differential input
E : - differential input
F : diagnostics
PE -
PIN 15
PIN 16
PIN 12
Module
8
7
6
5
16
15
14
13
12
11
10
9
Shield
Sensor X1
0... 10V / 4... 20mA
Power supply
24V
0V
Ready
Status
Sensor X2
0... 10V / 4... 20mA
4
3
2
1
0V
0V
0..10V
0..10V / 4... 20mA
P
E
te
rm
in
a
l
P
E
te
rm
in
a
l
RAMP/PSET
Start
Enable
Flow cmd Q
-10... 10V /
4...12...20 mA
Pressure cmd W
0... 10V / 4... 20mA
To power amplifier /
valve +/- 10V.
Use differential input.
For 4... 20mA use PIN 15 to PIN 11.