4.3 Timed/un-timed configuration.
The timed/un-timed configuration can be changed from the configuration selected by the DIL switch setting.
Timed/un-timed configuration is shown in the time area as t: 1 for timed operation and as t: 0 for un-timed operation.
1.
Press MENU until Set icon and t: are displayed.
2.
Current timed/un-timed configuration as set by DIL switch will be flashing.
3.
Adjust timed/un-timed configuration using
S
and
T
.
4.
Press OK to accept timed/un-timed configuration and advance to next item.
4.4 Timer period day mode (timed mode only).
Day mode is shown in the time area as d 1 for 1 day mode, d5:2 for 5/2 day mode and d 7 for 7 day mode. Likewise the day icons show as none for 1 day
mode, alternating MoTuWeThFr and SaSu for 5:2 day mode and MoTuWeThFrSaSu for 7 day mode.
1.
Press MENU until Set icon and d, in the time area, are displayed.
2.
Day mode configuration will be flashing.
3.
Adjust day mode configuration using
S
and
T
.
4.
Press OK to accept day mode configuration and advance to next item.
4.5 Temperature display mode (floor sensor only control mode).
Temperature display mode is shown in the time area as F: 0 for °C display and as F: 1 for 0-13 scale display.
1.
Press MENU until Set icon and F, in the time area, are displayed.
2.
Temperature display mode configuration will be flashing.
3.
Adjust temperature display mode configuration using
S
and
T
.
4.
Press OK to accept temperature display mode configuration and advance to next item.
4.6 Set PIN code.
1.
Press MENU until Set icon, PADLOCK icon and 0000 are displayed.
2.
The first 0 will be displayed flashing.
3.
Adjust PIN digit 1 using
S
and
T
.
4.
Press OK to accept digit 1. The second 0 will be displayed flashing.
5.
Adjust PIN digit 2 using
S
and
T
.
6.
Press OK to accept digit 2. The third 0 will be displayed flashing.
7.
Adjust PIN digit 3 using
S
and
T
.
8.
Press OK to accept digit 3. The fourth 0 will be displayed flashing.
9.
Adjust PIN digit 4 using
S
and
T
.
10.
Press OK to accept digit 4 and advance to next item in configuration menu.
4.7 Reset to defaults.
The control can be reset back to its default factory settings (including timer day mode, timer periods, control temperatures, default time and date etc) by using
the reset function.
To maintain safety the control will revert to the DIL switch settings, as set by the installer, for sensor configuration, timed/un-timed operation and the
maximum floor temperature.
1.
Press MENU until Set icon and dFLt in the time area are displayed.
2.
Press OK to enable reset to defaults.
3.
dFLt will be flashing.
4.
Press OK to confirm reset to defaults and return to normal operation.
5. User Settings
The MENU button is used to access User Settings for change by the user. The button is pressed until the appropriate icons for the item to be changed are
shown on the display.
If the user stops programming part way through a process then after 1 minute the control will automatically return to normal operation. Settings changed up
to that point will have been saved.
The menu button will only present settings that are relevant to the timed mode of operation when that mode has been selected.
The MENU button presents the settings in the following order:
•
Enter PIN (PIN enabled only)
•
Set tamper lock on or off (PIN not enabled only)
•
Floor temperature display (room and floor sensor mode only)
•
Set comfort temperature (timed mode only)
•
Set savings temperature (timed mode only)
•
Set minimum floor temperature (floor/room and floor sensor modes only)
•
Set timer periods (timed mode only)
•
Set time (timed mode only)
•
Set date (timed mode only)
•
Energy usage display
•