9. Install the spark plug by carefully following the steps outlined below:
a. Carefully insert the spark plug back into the cylinder head. Hand-thread the spark
plug until it bottoms out.
b. Using the spark plug socket wrench provided, turn the spark plug to ensure it is
fully seated.
c. Replace the spark plug boot, making sure the boot fully engages the spark plug’s
tip.
d. Install the spark plug access cover.
Recommended spark plug replacement:
NGK
Bosch
BPR6HS
WR7BC
Cleaning the spark arrestor
Check and clean the spark arrestor after every 100 hours of use or 6 months.
1. Stop the inverter and let it cool for several minutes if running.
2. Move the inverter to a flat, level surface.
3. Remove the screws holding the muffler cover in place (see Figure 19).
4. Loosen the clamp holding the spark arrestor onto the muffler.
5. Slide the spark arrestor band clamp off the spark arrestor screen.
6. Pull the spark arrestor screen off the muffler exhaust pipe.
Figure 20
(1) Valve, (2) Feeler Gauge Area
(3) Rocker Arm, (4) Jam Nut, (5) Adjusting Nut