Chapter 4
Nonvolatile Configuration
© National Instruments Corporation
4-5
GPIB-VXI User Manual
Set Configuration to Factory Settings
The item
Set Configuration to Factory Settings
sets the contents of the RAM
copy of the NV memory to the default (original) factory settings. Notice that only the RAM
copy is affected. The NV memory must be written back using the
Write Back (Save)
Changes
command in the main menu to retain the changes after the GPIB-VXI has been reset
or powered-down.
Write Back (Save) Changes
The item
Write Back (Save) Changes
writes the modified copy of the NV memory
back to the EEPROM. The write-back procedure takes from five to ten seconds.
Quit Configuration
The item
Quit Configuration
prompts you to select a different startup configuration, or
re-enters pROBE, depending upon how the diagnostics were entered.